SECTION 100-006-200
INSTALLATION INSTRUCTIONS
DECEMBER 1982
06.24
For protection against static
electricity,
a
green
jumper
wire
is
attached to the
11
FG
11
screw (refer to
Figure 8).
This wire must be connec-
ted to the
11
0V
11
terminal on the MTOU
power strip.
Reinstall the plastic pro-
tective cover
on
the
power strip at
this time.
06.25
The Toshiba STRATA VI elec-
tronic key telephone system requires a
solid earth ground on the
11
FG
11
terminal
on the MKSU tray.
Failure to provide
such a ground
may lead
to confusing
trouble symptoms in the system and, in
extreme cases, circuit board failure.
e
In
most
installations,
within
the
continental
United
States,
the
ground provided by the
11
third wire
ground
11
at
the
commercial power
outlet will be satisfactory for all
STRATA
VI
requirements.
llow-
ever, in a small percentage of in-
stallations
this
ground
may
be
installed
incorrectly.
Therefore,
prior
to
installing a STRATA
VI
system, the third wire ground must
be tested for continuity by either
measuring
the
resistance
between
the
3rd
prong
terminal
(earth
ground)
and
a
metal
cold
water
pipe, or by using
11
commercially
available
emth
f~round
indicntor.
lf
neither of these procedures are
possible, then the
test
procedures
outlined in Parngrnph 06.26 should
be performed.
CAUTION:
Hazardous voltage is exposed
during
the
following
test.
Use great care when working
with AC powerline voltage.
06.26
Test Procedure
1.
Obtain a suitable voltmeter and set
it for a possible reading of up to
250VAC.
2. Connect the meter probes between
- 6 -
the two main AC voltage points on
the wall outlet.
The reading ob-
tained should
be
90"-'l30VAC.
3. Move one of the meter probes to
the
3rd
prong
terminal
(GND).
Either
the
same
reading
or
a
reading of 0
volts should be ob-
tained.
4. If the reading
is
OV,
leave
one
probe
on
the
GND
terminal
and
move the other probe to the 2nd
voltage terminal.
If a reading of
OV
is
obtained
on
both
voltage
terminals,
the
outlet
is not
pro-
perly grounded.
Omit Steps 5 /'./ 7,
and proceed directly to Step 8.
5. If a reading of OV on one terminal
and a reading of 90
~
130VAC on
the other terminal is not obtained,
the outlet is not properly groun-
ded.
Omit Steps 6 &: 7, and pro-
ceed directly to Step 8.
6.
If
a reading of OV on one terminal
and a reading of 90/\/130VAC on
the other terminal is obtained, re-
move both probes from the outlet.
7. Set the meter on the noHMS/Rxir'
scale, place one probe on the G ND
terminal
and
the
other
probe
on
the terminal which gave a reading
of OV.
A reading of less than one
ohm
should
be
obtained.
If
a
reading of less the one ohm is not
obtained,
the
outlet
is
not
ade-
quately grounded.
8.
If
the above tests show that the
outlet
is
not
properly
grounded,
that condition should be corrected
(per
Article
250
of
the
National
Electrical
Code)
by
a
qualified
electrician before the STRATA VI
system is
conn(~cted.
06.27
Ensure that the power switch
on the MTOU
is OFF, then plug
the
power supply into
the 115VAC outlet