SECTION 100-006-200
INSTALLATION INSTRUCTIONS
DECEMBER 1982
through the STRATA
VI over
ex-
ternal speaker(s):
a) Adjust
voice
page
level
per
above procedure.
b) With
music
playing
over
the
speaker(s), adjust the volume to
a comfortable level using only
the BGM control on the
front
of the MTOU.
Do not
tamper
with the
EX.SP
control, exter-
nal
amplifier
adjustments,
or
MOH adjustments.
c)
If
background
music
is
con-
nected directly to the external
amplifier instead of through the
system, all adjustments must be
made on the external amplifier.
11.84
If no external speak er is to
be used in the system, adjust
the BCM
level as follows:
1) Using an EKT in the spcakerphone
mode, make a call on
11
CO line,
and adjust the EKT speaker to a
comfortable level.
NOTE:
This
area
that
that
tion.
should
be
done
in
an
'Jfi th
background
noise
is
about
average
for
particular
ins talla-
2)
Disconnect the CO eall 1rncl neti-
vate
BG M
at
the
EKT using ti1c
CS-PKRJ
key.
3) Using only the BG M volume eon trnl
on the front of the M TOU, acljust
the BGM to a eornfortablc level.
Do not use the EKT volume eontrol.
11.90
Night Relay
Service
11.91
As an option,
tlic
STRATA VI
can
provide
a
dry
contact
for
the
purpose of con trolling an exterrw.l lou<i
ringing bell (or similar device) or an
answering machine when the system is
in the
11
Nite
11
mode.
11.92
To provide
this service,
ob-
tain and install the optional NR
(K 2)
relay on the MTOU PCB per Paragraph
05.01.
Connect the external device to
the N
R
contacts on the front of the
lVITOU.
IMPORTANT:
The NR and BR relay contacts
are
rated at 24 VDC/1.0
Amp
and
are
not intended
to
op-
erate
high
power
devices
directly.
If
the
power
re-
quired
for
the device being
controlled
exceeds
the con-
tact
ratings,
an
external
slave relay
must
be used.
11.93
The
W 3 strap option on the
!VlTOU nllows the
N R
relay to function
m one of two mocles (see Figure
4).
a) Answering Machine Control-if the
W3 strap remains intact, the relay
is operated continuously when the
system is in night service.
This
mode
is
in tended
for
indirect
control of an answering machine.
b)
Night Bell Control-if the W 3 strap
ic: cut, the relay pulses at a 1-sec.
on,
3-sec.
off
rate
when
the
system is in night service and an
incoming
call
is
ringing
the
sys-
tem.
The mode is intended to be
used
for
indirect
control
of
an
external night bell.
- 22 -