Download Print this page

Toshiba Strata VI Installation Instructions Manual page 18

Electronic key telephone system

Advertisement

tional
handset
hanger
kit
(available
from
your
Toshiba supplier)
must
be
used whenever the EKT is wall-mounted.
Handset
Hanger
Nurnber Card
Card Cover
FIGURE 24
08.22
Remove the card cover by in-
serting a paper clip in the hole at one
end.
Bend the cover up and remove it
and the number card.
08.23
Install
the
handset
hanger
in to place and tighten the self-tapping
screws.
Reinstall the number card and
card cover
and
connect
the
modular
plug to the modular jack.
09
SYSTEM POWER-UP INITIALIZE
09.01
The STRATA VI has a list of
standard system data assignments stored
in ROM that can be entered at any
time
by
performing
the
initialize
sequence outlined below.
The system
must
be
initialized
when
it
is
first
installed or whenever the MCCU PCB
is changed.
This will allow the system
to
be
tested
and
any
faults
to
be
corrected
before
time
is
spent
on
programming.
SECTION 100-006-200
INSTALLATION INSTRUCTIONS
DECEMBER 1982
NOTE:
Do not initialize if using a
pre-programmed, battery-pro-
tected HCCU.
09.02
Ref er to Figure 25 and verify
that
the battery on
the
MCCU (and
CRDU,
if
equipped)
is
connected
to
ensure that data changes entered after
initialization will not be lost due to
power failure.
NOTE:
The SET LED will not
func-
tion if the MCCU battery is
not connected.
Sl'.3 BATTERY STR,\P
SW! BATTERY STRAP
FIGURE 25
09.03
To initialize the system data
memory, ref er to Figure 26 and perform
the following steps:
a) Place
the
power
switch
on
the
MTOU PCB in the
ON
position.
b)
Depress
the
INT
switch
on
the
MCCU, and hold it in.
c) Depress the SET switch and allow
it to lock.
- 15 -