5.5.5.4 Dehumidification program
The condensation of water in the insulation of the firing chamber
and the vacuum pump will result in a lower vacuum and thus to
impaired firing results. For that reason, the furnace head should be
kept closed when the furnace is switched off, in order to prevent
the absorption of humidity. Start the dehumidification program if
required (humidity in the insulation).
5.5.5.5 Keypad test
Each time the keypad is pressed, a short beep sounds. The keypad
test can be ended by pressing ESC.
5.5.5.6 Display test (page 2 / 2)
Two different "chequer-board patterns" are alternately shown on the
entire display. This allows the visual check of each individual pixel.
The display test can be ended by pressing ESC.
5.6 Description of the symbols in the display
Symbol Name
Meaning
Pre-vacuum
Vacuum generation
starts before the
heating begins.
"One-stage
Abstract firing curve
program"
of a one-stage
program
"Two-stage
Abstract firing curve
program"
of a two-stage
program
"Standard opening
Furnace head opens
of the furnace
in the standard
head"
period of time
"Quick opening of
Furnace head opens
the furnace head"
in a short period of
time, i.e. quicker
(arrow)
Open lock
"Individual write-
protection inactive"
Closed lock
"Individual write-
protection active"
Crossed-out
"Overnight program
"crescent moon"
inactive"
"Crescent moon"
"Overnight program
active"
Open furnace head
"Pre-drying active"
with heat rays
"Individual group
All 10 programs of
write-protection
this group are write-
active"
protected
"General write-
All programs are
protection active"
write-protected
Press mode or note
For selecting the
on the active press
Press mode. If the
procedure
press process has
been started, this
symbol is shown next
to the remaining
pressing time.
24