Jenn-Air JID4436ES Installation Instructions Manual page 9

36" 91.4 cm downdraft touch-activated electronic induction cooktop
Hide thumbs Also See for JID4436ES:
Table of Contents

Advertisement

Available languages

Available languages

Electrical Requirements
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path and wire gauge are in accordance with
local codes.
Check with a qualified electrical installer if you are not sure the
cooktop is properly grounded.
Make sure that the electrical connection and wire size are
adequate and in conformance with the National Electrical Code,
ANSI/NFPA 70 - latest edition or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No. O-M91 - latest
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Before You Make the Electrical Connection:
To properly install your cooktop, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
A 3-wire or 4-wire, single phase, 120-/240-volt, 60 Hz,
AC-only electrical supply on a separate, 40-amp circuit
breaker is required. If a fused system is used, fuse both
sides of the line.
The cooktop should be connected directly to the junction
box through the flexible metal conduit. The flexible, armored
cable extending from the fuse box or circuit breaker box
should be connected directly to the junction box.
Locate the junction box to allow as much slack as possible
between the junction box and the cooktop so that the
cooktop can be moved if servicing becomes necessary
in the future.
A UL listed or CSA approved conduit connector must
be provided at each end of the power supply cable
(at the cooktop and at the junction box).
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the
pigtail leads.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
INSTALLATION INSTRUCTIONS
Prepare Cooktop
WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
1. Open product as instructed on product packaging.
2. Remove shipping materials and tape from cooktop.
3. Using 2 or more people, remove the cooktop from
the carton.
NOTE: Always handle the cooktop from the underside of
the cooktop chassis, not from the stainless steel frame or
the metal covers on the bottom of the cooktop.
4. Using 2 or more people, place the cooktop upside
down on a protected surface.
9