Start Up Recommendations (Continued) - TCS 700-30 Installation, Operation & Maintenence Manual

Rotary meter
Table of Contents

Advertisement

Start-Up Recommendations (CONTINUED)
15). When operating the meter with accessories, valves should be opened slowly to avoid a pressure
surge that can damage the meter or air eliminator. System pressures should be maintained below
70 PSI (4.9 BAR).
16). Custody transfer metering systems must be calibrated by a regulatory agency before product can
be sold off the meter. Contact your local authorities for proper calibration.
17). Strainers should be cleaned frequently or have a maintenance schedule. This will ensure a clean
system and long service life.
Direction of Flow
The meter is set up at the factory for left to right flow. To change the meter to right to left flow, begin
by removing the screws (#9 on the Meter Assembly Breakdown) and the adjuster cover plate (#7) on the
front of the meter. Remove both the screws (#1), the drive shaft retainer (#10), the drive shaft (#3), the
e-ring (#4) and the face gear (#5). Reinstall the gear on the shaft with the gear teeth facing up. Snap the
e-ring back into place to hold the gear in place. Reinstall the shaft, mating the face gear with the drive
gear of the packing capsule assembly. Reinstall the screw and cover plate. The meter will now be set
up for right to left flow. See Page for a parts breakdown of entire meter assembly.
Page 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

700-35

Table of Contents