8.4
�ehicleLogoReplacement
There are two vehicle logo replacement methods: single
replacement and integral replacement, with the single
replacement taken as the default mode. The picture
size is 136*115 (mm) and the picture format is bmp.
8.4.1
SingleReplacement
Only one vehicle logo can be replaced one time.
Operation Steps:
1. Select "Single Replacement";
2. Select the vehicle logo to be replaced in the left
dropdown box;
3. Select the target vehicle logo on the right;
4. Click the
button in the middle to synchronize
logos at both sides; at the same time, the replace-
ment button changes to the available status;
5. Click the "Replace" button.
8.4.2
�ntegralReplacement
Several vehicle logos can be replaced one time.
Operation Steps:
1. Select the "Integral Replacement";
2. Click the "Browse" button to select the target pic-
ture folder, and its path shall correspond with the
path in the CF card;
3. Click the "Replace" button.
Bosch Automotive Diagnostics Equipment (Shenzhen) Limited
�ehicleDiagnostic|���|19
9.
Vehicle Diagnostic
Main Interface of Vehicle Diagnosis:
No.
Description
The main function area, including vehicle diagnosis, ve-
hicle analyzer and service help;
The system function area, including screenshot, play-
back, setting, help and feedback;
The display area for vehicle series, including All, Chinese,
American, European, Japanese, Korean, OBD-II and his-
tory record;
The display area for testable vehicle models, including all
testable vehicle models of each vehicle series;
The display area for additional functions, including brand
search;
The status column, including diagnosis path, VCI connec-
tion status and VMI connection status;
The scrolling bar, which can be dragged for viewing con-
tents of multiple screens when the displayable contents
are in more than one screen.
9.1
Test�onditions
R
The vehicle power switch turned on;
R
The vehicle battery voltage at 12V or 24V;
R
There is communication between the host and PC .
9.2
Powersupplyofhost
There are 4 power supply modes for VCI host, you can
select according to your requirement:
R
AC power supply: take out VCI standard configura-
tion power adapter in the instrument; Connect one
end to the power interface of the instrument and
another end to 100~240V AC socket;
R
Automobile battery cell power supply: take out
KT600 standard configuration power extension lead
and alligator clip; connect one end to the power in-
terface of the instrument and another end to battery
end;
R
Cigarette lighter power supply: take out VCI standard
configuration power extension lead and cigarette
lighter; connect one end to power interface and ano-
ther end to cigarette lighter;
R
Diagnosis retainer power supply.