Gilera 633721 Workshop Manual page 230

Table of Contents

Advertisement

Injection
To replace the components, proceed as follows:
(1) Level indicator:
- Note the assembly position and the path of the
two connecting wires.
pos 2 = wire connected to the circuit
pos 3 = wire connected to the movable arm
Pass the wires through the hole found between fil-
ter and pressure regulator.
- Disconnect and extract the wires
- Using a screwdriver on the retain tab as shown
in the figure, extract the level indicator from the
support
- Level indicator check
The check may also be carried out before removing it from the support.
Measure the resistance between the two level indicator wires.
Moving the float arm, check that the resistance is subject to gradual variations according to the arm
motion.
1
2
- To refit, repeat the removal operations but in reverse order.
(2) Pressure regulator:
- Remove the locking spring
- Extract the pressure regulator with sealing rings.
N.B.
INJEC - 230
LIMIT VALUES
Specification
Empty tank position:
Full tank position:
Nexus 500 euro 3
Desc./Quantity
95 - 105 Ω
0 - 9 Ω

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexus 500 euro 3633728

Table of Contents