Figure 19. Secure The Anode Wire - EarthLinked AVS-0030-A Quick Start Instructions

Classic series sd (h) geothermal heating and cooling system
Table of Contents

Advertisement

Once the gland nut has been hand tightened into the plug body, use two adjustable wrenches to
further tighten the gland nut until it is snug in the plug body as shown in Figure 19 and the anode
wire is held firmly in the plug body and will not slip out. Do not over-tighten the gland nut!

Figure 19. Secure the Anode Wire.

After the plug and anode wire have been assembled, re-connect the sealing cap assembly tool to
the socket on the compressor unit cabinet. After aligning the electrical contact pins, manually
engage the threads on the plug locking cap with the threads on the socket and turn clockwise until
the plug is firmly hand-tightened to the socket as shown in Figure 20. If the anode wire rises away
from the compressor cabinet, be sure to shape a drip loop into the contour of the anode wire near
the plug and socket.
Figure 20. The Plug and Socket Joint
After the plug and socket joint is secured, the power may be turned ON at the disconnect.
SD-410-QS (H) (06/15)