4. Storage Water Heater: The GSTE Series storage water heaters are available from ETI in 60,
80 and 119 US Gallon capacities, and are designed for use with the EarthLinked
systems. They are equipped with a 4.5 kW supplemental heater which satisfies the ETI
requirement for a minimum of 20% supplemental heat.
5. Other Plumbing Components and Parts: Gate valves, unions, copper pipe, pipe insulation,
etc. meeting USA industry and local code standards are commercially available through
plumbing supply outlets.
All plumbing installations are to be in accordance with the applicable local and national codes.
The heat exchanger must be isolated from the water system when the
system undergoes a "superchlorination" or "shock chlorination"
flushing process. Closing the isolation valves as shown in Figure 11
prior to initiating the system flushing process isolates the heat
exchanger. The water entering the heat exchanger after the system
flushing must not exceed a chlorine level consistent with the local
municipal water purification standards. Failure to isolate the heat
exchanger will damage the heat exchanger causing system failure.
Allowing highly chlorinated water to enter the heat exchanger will void
the EarthLinked