Download Print this page

G-Tech FIELD MATE User Manual And Installation Manual page 9

Spreader rate controller and area meter

Advertisement

Dump Mode
Dump mode is used to empty the spreader or to calibrate the spreader to output 1 tonne of material.
Calibrate the Spreader to output 1 tonne for material.
1. Goto DUMP mode.
2. Quick press the power button to enter DUMP mode.
Speed of the Spinner in DUMP MODE. In a Twin floor system, this is under Mechanical
control. In Single floor mode the DUMP RPM is set in the SETUP Screens.
Chain RPM during DUMP MODE. Hold the
buttons to achieve the desired RPM.
5or 6
3. Quick press the
will flash.
- Hold down the
5 or 6
- When the spreader has output 1 tonne the chains will stop.
Note 1: The weight and material output and based on the current material being spread. Accurate weight
calc is based on the exact door open measurement setting and the correct material density.
Note 2: The spreader must have a one tonne amount of material placed in the spreader if this calibration is
to be accurate. Then this 1 tonne is measure out to test spreader output calibration.
Note 3: If the Spreader stops at 1 tonne but with 100kg of material left in the spreader then this is
concidered a 10% over weighing. To fix reduce the Floor Factor by 10%.
Note 4: If the Spreader has output all the material when the weight is 900kg, then the spreader is
concidered to be 10% under weighing. To fix increase the Floor Factor by 10%.
Keep working with the FLOOR FACTOR number until 1 tonne of material is output from the spreader
when a 1 tonne bag is entered into the spreader.
button will put the spreader in to Dump Tonne mode. In this mode the TONNE label
5
buttons to make the chain start.
Weight out put by Spreader as calculated by the monitor, based
on internal settings and Material density and door opening.
The Chain RPM and rotations of the Chain motors are counted.
TONNE flashes when in dump tonne mode.
Page 9

Advertisement

loading