S 7546
..........
,
.5
7
As it passes through the compressor, the heat- '
carrying vapour is pressurized and reaches a
temperature that is considerably higher than
that of the ambient air. The vapour proceeds to
the condenser where it gives up its heat and re-
turns to a liquid state (condenses). The conden-
sation (the condensed refrigerant) is filtered, de-
siccated and stored under pressure in the re-
ceiver. The expansion valve meters the refrige-
rant into the evaporator, whereupon the pressure
drops. This causes the refrigerant to boil (evapo-
rate).
Anga, Iflgtryck
Low pressure. vapor
Niederdruck. gasformig
Vapeur. basse pression
Vatska, Iflgtyck
Low pressure. liquid
Niederdruck. flussig
Liquide. basse pression
Saab900
9
Cirkulation diagram
1 Compressor
2 Condenser
3 Receiver shell
4 Expansion valve
5 Evaporator
6 Temperature-sensitive expansion valve body
7 Compensating hose
8 Anti-freezing thermostat
9 Temperature-sensitive anti-irostthermostat body
1
6
••••••
I
I
I
.., .' I
I
I
I
I
1J.
I
I
___.J
Anga. hiigtryck
High pressure. vapor
Hoctldruck. gasformig
Vapeur, haute pression
854-14 Heating and ventilation system, air conditioning system
Operating principle
The main components in the mechanical system
are the evaporator, compressor, condenser,
themostatic expansion valve, anti-frosting ther-
mostat and dryer receiver.
The
refrigerant"·-abs'Orbs'
' + ;e' 8 ' t -
inside
the
evaporator by· changing
from"a-~liquid
into a va.:.
pour. The air which flows 'over the"fins of the
evaporator is cooled and demoisturized.
Cycling clutch system as from the 1980
models