11. ERROR MESSAGES

When you turn on the device, it will first perform a reset. The display may show "Err channel is
XX" should there be problems with one or more functions. "XX" stands for channel 1, 2, 3, 4, 5,
6 etc whose sensor has encountered a problem. For example, when the display shows "Err
channel is Pan movement", it means there is an error on channel 1. If there are errors on channel
1, channel 3, channel 6 at the same time, you may see the error message, "Err channel is Pan
movement", "Err channel is Tilt movement"" "Err channel is Shutter" ,flash twice, and then the
device will generate a second reset. If the error messages persist after performing a reset more
than twice, the channels which have errors may not work properly however, all other functions
can work as usual. Please contact your dealer or manufacturer for service. Self repair is not
allowed.
PAN- movement Er
(PAN- yoke movement error) This message will appear after the reset of the fixture if the yoke's
magnetic-indexing circuit malfunction (Optical Sensor or Magnetic Sensor fails) or the stepper
motor is defective (or its driving IC on the main PCB). The PAN- movement is not located in the
default position after the reset.
TILT- movement Er
(TILT- head movement error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions ((Optical Sensor or Magnetic Sensor fails)) or the stepper
motor is defective (or its driving IC on the main PCB). The TILT- movement is not located in the
default position after the reset.
FOCUS- movement Er
(FOCUS- head movement error) This message will appear after the reset of the fixture if the
head's magnetic-indexing circuit malfunctions ((Optical Sensor or Magnetic Sensor fails)) or the
stepper motor is defective (or its driving IC on the main PCB). The FOCUS - movement is not
located in the default position after the reset.
ZOOM- movement Er
(ZOOM- head movement error) This message will appear after the reset of the fixture if the
head's magnetic-indexing circuit malfunctions ((Optical Sensor or Magnetic Sensor fails)) or the
stepper motor is defective (or its driving IC on the main PCB). The ZOOM - movement is not
located in the default position after the reset.
COLOR- movement Er
(COLOR- head movement error) This message will appear after the reset of the fixture if the
head's magnetic-indexing circuit malfunctions ((Optical Sensor or Magnetic Sensor fails)) or the
stepper motor is defective (or its driving IC on the main PCB). The COLOR - movement is not
located in the default position after the reset.
CMY wheel Er
(CMY wheel- error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is
defective (or its driving IC on the main PCB). The CMY - movement is not located in the default
position after the reset.
CTO wheel Er
(CTO wheel- error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is