BOON EDAM THT-100 Operation, Installation, And Maintenance Manual page 29

Full height turnstile
Table of Contents

Advertisement

THT-100
Ceiling Plate and Top Channel Connection
The ceiling plate mounts to the top of the shield assembly. Gaskets fit between the ceiling plate
and each endpost Four M10 bolts connect the ceiling plate to the shield assembly. Four M10
bolts, lock washers and flat washers connect the top channel to the mid-post of the shield and
barrier post.
Figure 5-13: Top Channel and Ceiling Plate Bolt Connections
Boon Edam Inc.
402 McKinney Parkway
Tel. 910-814-3800 fax 910-814-3899
4 x M10
Bolt/Flat/Lock
Hardware Used in this Process
Qty
Part #
6
HW038
6
HW003
6
HW019
2
Two additional M5 bolts, and lock washers
and connect the shield up into to the top
channel.
Hardware Used in this Process
Qty
2
2
4 x M10
Bolt/Flat/Lock
Description
M10 x 1.5 x 20 Bolt
M10 Spring Lock Washer
M10 Washer
Ceiling Plate Gasket
Part #
Description
HW001
M5 x 8 Socket
HW016
M5 Spring Lock Washer
Version: Rev A6 10/28//2011
Issue: THT-100-IMM-USA
28
Gasket

Advertisement

Table of Contents
loading