5.1.7 Connecting Cables to the AP-IFU

Connect four cables to the AP-IFU: a coaxial cable (with an N connector), optical cable, outdoor
power supply cable, and ground wire.
Round connector for
the power cable
terminal
Ethernetl cable
inlet
Ethernet cable
Figure 5-12-1 Connecting Cables to the AP-IFU (on the AP-PWR Side)
CAUTION: Ground wire more than 1.5□
CAUTION: FG terminal wire more than M4nut.
CAUTION: The DC -48V power supply voltage for AP-IFU shall be SELV or TNV-1 depending on
the network environment (0 or 1) acc. to IEC62102.
CAUTION: The Equipment for connection to AP-IFU Ethernet-interface(RJ-45) shall be appropriate
to connect to TNV-1 circuits.
CAUTION: For the connection Terminal Equipment to AP-IFU and a cables suitable for outdoor use shall
be installed.
FG terminal
(More than M4nut)
Ground wire
(More than 1.5□)
Outdoor power supply cable for the AP
Cold-shrinkable sleeve
5-28
Coaxial cable with an
N connector (IF cable)