(2) State transition
The table below shows how each LED changes its state after the power is turned on until the unit
becomes operable.
Table 4-2 LED State Transition when the Power is Turned On
Immediately
after the power
is turned on
POW
Lit
ETHER
Extinguished
(Extinguished)
ALM
Extinguished
*Flashing for 500msec. (On for 500msec. and off for 500msec.)
(3) Lighting conditions
The table below shows when the ALM LED lights.
Table 4-3 Lighting Conditions of the ALM LED in the Out-of-Service State
Operation state
During authentication
During operation
Carrier off
*Flashing for one second (On for one second and off for one second)
Several
Radio
seconds
synchronization
after the
power is
turned on
Lit
Lit
Lit
Extinguished
(Lit)
(Lit/Flashing)
Lit
Lit
Out of service
ALM LED=Extinguished
ALM LED=Flashing*
ALM LED=Extinguished
Authenticating
after radio
lost
synchronization
is reestablished
Lit
Extinguished
(Lit/Flashing)
Flashing*
Out-of-service state
ALM LED=Extinguished
ALM LED=Extinguished
ALM LED=Extinguished
4-20
Operating after
Remarks
authentication is
finished
Lit
Extinguished
The state
(Lit/Flashing)
within
parentheses
is that when a
PC is
connected.
Extinguished
Cleared