Further Settings - Pfaff 8320-020 Instruction Manual

8320 series; 8321 series
Table of Contents

Advertisement

11

Further settings

.03
The further settings are use for stipulating further machine settings, the choice of country
and access rights.
● Switch on the machine.
● Call up the input mode.
● Call up the input menu for further settings.
Description of the functions
Input menu
This function is used to call up the input menu.
Sealing mode
This function is used to change to the sealing mode.
Feed unit backwards after stop
This function is used to enter the distance which the feed unit should move back after a
sealing stop.
Feed unit forwards at end
The function can be switched on or off. When the function is switched on, the distance,
which the feed unit should continue moving after the end of sealing, can be entered.
Temperature window for sealing start
This function is used to enter the tolerance between the actual and the set temperature,
within which a sealing start is possible. If the actual temperature is outside the tolerance ,
the sealing start is blocked.
Flip-fl op mode (pedal)
This function is used to switch the fl ip-fl op mode for the pedal function on or off:
- Function switched on (symbol shown inverse)
The pedal function is only carried out as long as the pedal is held in the appropriate
position.
- Function switched off
The pedal function is carried out as soon as the pedal is brought into the appropriate posi-
tion and remains active after the pedal has been released.