Commissioning - Pfaff 8320-020 Instruction Manual

8320 series; 8321 series
Table of Contents

Advertisement

8

Commissioning

.02
● Examine the machine, in particular the electric leads, for any damage.
● Clean the machine thoroughly, also see Chapter 12 Maintenance.
● Connect the machine to the electrical network and have specialists examine, whether the
machine can be operated with the available voltage and whether it is properly connected.
Fig. 8 - 02
Do not operate the machine if there is any discrepancy!
The machine may only be connected to an earthed socket!
1
0.4
0.6
0.2
0.8
0
1
+
-
Installation and commissioning
● Connect the machine to the compressed
air system. A pressure of 6 bar should
be displayed on the manometer. If neces-
sary, set this value, see Chapter 12.02
Checking / adjusting the air pressure.
The air must be completely oil-
free and dry.
The compressed air quality
influences the service life of the
heating cartridge in the air
heater. If the air is very damp,
a compressed air cold drier with
preliminary filter and secondary
fine filter must be installed in
front of the heat-sealing
machine
134-010
23