Technical Data - ABB PSR Manual

Softstarters
Table of Contents

Advertisement

PSE – The efficient range

Technical data

Rated insulation voltage U
i
Rated operational voltage U
e
Rated control supply voltage U
Rated control circuit voltage U
Starting capacity at I
e
Number of starts per hour
Overload capability,
Overload Class
Ambient temperature
During operation
During storage
Maximum Altitude
Degree of protection
Main circuit
Supply and Control circuit
Main circuit
Built-in By-pass
Cooling system - Fan cooled
(thermostat controlled)
HMI for settings
Display
Keypad
Main settings
Setting current
Ramp time during start
Ramp time during stop
Initial / end voltage
Current limit
Torque control for start
Torque control for stop
Kick start
Signal relays
Number of signal relays
K2
K3
K1
Rated operational voltage U
e
Rated thermal current I
th
Rated operational current I
e
at AC-15 (U
= 250 V)
e
Valid for 50 % on time and 50 % off time. If other data is required, please contact your sales office
1)
2)
Above 40 ºC up to max. 60 ºC reduce the rated current with 0.6 % per ºC.
When used at high altitudes above 1000 meters up to 4000 meters you need to derate the rated current using the following formula.
3)
= 100 - x - 1000 ] x = actual altitude for the softstarter
[ % of I
e
150
A common voltage needs to be used for all 3 signal relays
4)
600 V
208 ... 600 V +10 %/-15 %
100 ... 250 V +10 %/-15 %, 50/60 Hz ±5 %
s
Internal 24 V DC
c
4xI
for 10 sec.
e
10
1)
10
-25 ... +60 °C
2)
-40 ... +70 °C
4000 m
3)
IP00
IP20
Yes
Yes
4 7-segments and icons. Illuminated
2 selection keys and 2 navigation keys
Size dependent
1-30 sec
0-30 sec
30-70%
1.5-7xI
e
Yes / No
Yes / No
Off, 30-100%
3
Run signal
TOR (By-pass) signal
Event signal
250 V AC / 24 V DC
4)
3 A
1.5 A
Analog output
Output signal reference
Type of output signal
Scaling
Control circuit
Number of inputs
Signal indication LED's
On / Ready
Run / TOR
Protection
Fault
Protections
Electronic overload
Locked rotor protection
Underload protection
Field bus connection
Connection for
ABB FieldBusPlug
External keypad
Display LCD type
Ambient temperature
during operation
during storage
Degree of protection
Time (s)
10 000
1000
100
10
1
0
0
1
2
3
Tripping curves for electronic overload protection (Cold)
4 ... 20 mA
I Amp
Fixed at 1.2 x I
e
3 (start, stop, reset of faults)
Green flashing / steady
Green flashing / steady
Yellow
Red
Yes (Class 10A, 10, 20, 30)
Yes
Yes
Yes (option)
-25 ... +60 °C
-40 ... +70 °C
IP66
4
5
6
7
8
Current (x I e )
1SFC132005C0201, rev.F | Softstarters 33
Class 30
Class 20
Class 10
Class 10A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

PssPstbPse

Table of Contents