3. ADC calibration
Note: After replacing main board, please execute ADC
calibration.
(1.) PC Calibration
Equipment:
- Video generator (output level: 700 mv)
Test signal:
- Timing:800 x 600 @60Hz
Test pattern:
- Grays 16.
Criteria
- Check if the ADC calibration status has
changed from Doing to Done.
Procedure
- On the IR remote keypad, press Menu >
Size & Position > Size Presets > Full Size.
- Enter factory mode.
- Select ADC Calibration > Help.
- After a few seconds, the ADC calibration
status will change from Doing to Done.
(
2.) Video Calibration (For BNC port)
Equipment:
- Video generator (output level: 700 mv)
Test signal:
- Timing:1280x800@60Hz(WXGA)
Test pattern:
- SMPTE BAR.
Criteria
- Check if the ADC calibration status has
changed from Doing to Done.
Procedure
- Input the signal from BNC port.
- On the IR remote keypad, press Menu >
Size & Position > Size Presets > Full Size.
- Enter factory mode.
- Select ADC Calibration > Help.
- After a few seconds, the ADC calibration
status will change from Doing to Done.
1920x1200@60Hz(WUXGA)
Grays 16
SMPTE BAR
EK-815U
Confidential
4-10