TABLE 8
Specification
Input system power (including power supply and fan
FRUs)
Input voltage
Input line frequency
BTU rating
Inrush current
Input line protection

Environmental requirements

Table 9
during transportation or storage) conditions.
TABLE 9
Condition
Ambient
Temperature
Humidity
Altitude
Shock
Vibration
Air flow
Heat dissipation

General specifications

Table 10
TABLE 10
Specification
Configurable port types
System architecture
System processor
ANSI Fibre Channel protocol
Modes of operation
Fabric initialization
FC-IP (IP-over-Fibre Channel)
Brocade 8000 Hardware Reference Manual
53-1001234-04
Power Supply Specifications
lists the acceptable environmental ranges for both operating and nonoperating (such as

Environmental requirements

Acceptable during operation
0º to 40º C
32º to 104º F
10% to 85% RH non-condensing, at
40º C (104º F)
0 to 3 km (9,842 feet) above sea level
20 G, 6 ms, half-sine wave
0.5 G sine, 0.4 gms random, 5-500 Hz
Maximum - 71.36 cmh (42 cfm)
Nominal - 59.47 cmh (35 cfm)
1044 BTU/hr (32 port configuration)
lists the general specifications for the Brocade 8000.

General specifications

Environmental requirements
Value
Idle: 206 W
Maximum: 306 W
85-264 VAC
47-63 Hz
1044.11 BTU/hr
Maximum of 60A for period of 10-150mS
Both AC lines are fused
Description
F_Port, FL_Port, E_Port, and M_Port
Nonblocking shared-memory switch
Freescale MPC8548 x 1.3GHz
FC-PH (Fibre Channel Physical and Signalling Interface standard)
Fibre Channel Class 2 and Class 3
Complies with FC-SW-3 Rev. 6.6
Complies with FC-IP 2.3 of FCA profile
Acceptable During Non-Operation
-25º to 70º C
-13º to 158º F
10% to 90% RH non-condensing, at 70º C
(158º F)
0 to 12 km (39,370 feet) above sea level
33 G, 11 ms, half-sine wave, 3/eg Axis
2.0 G sine, 1.1 gms random, 5-500 Hz
NA
NA
A
37