A

Environmental requirements

Environmental requirements

Table 6
during transportation or storage) conditions.
TABLE 6
Condition
Ambient
Temperature
Humidity
Altitude
Shock
Vibration
Air flow

General specifications

Table 7
TABLE 7
Specification
Configurable port types
System architecture
System processor
ANSI Fibre Channel protocol
Modes of operation
Fabric initialization
FC-IP (IP over Fibre Channel)
Aggregate switch I/O bandwidth
Port-to-port latency
30
lists the acceptable environmental ranges for both operating and nonoperating (such as
Environmental Requirements
Acceptable During Operation
0
to 40
Celsius

(32
to 104
Fahrenheit)
10% to 85% RH non-condensing, at
40 Celsius (104
gradient of 10% per hour
3,000 meters (9,842 feet) above sea level
20 G, 6 ms, half-sine wave
0.5 G sine, 0.4 grms random, 5-500 Hz
High speed, 13,000 RPM,
Low speed, 7000 RPM,
lists the general specifications for the Brocade VA-40FC.

General Specifications

Fahrenheit), with maximum
49.3 CMH
(29 CFM)
37.4 CMH
(22 CFM)
Description
E_Port, F_Port, FL_Port, M_Port, and EX_Port
Nonblocking shared-memory switch
Power PC 440EPX,667 MHz CPU
FC-PH (Fibre Channel Physical and Signalling Interface standard)
Fibre Channel Class 2 and Class 3
Complies with FC-SW-3 Rev. 6.6
Complies with FC-IP 2.3 of FCA profile
640 Gbps if all 40 ports are running at 8 Gbps, full duplex
700 nanoseconds
Acceptable During Non-Operation
-25
to 70
Celsius
(-13
to 158
Fahrenheit)
10% to 90% RH non-condensing, at 70°
Celsius (158
Fahrenheit)
0 to 12 kilometers (39,370 feet) above sea
level
Half sine, 33G 11ms, 3/e.g. Axis
2.0 G sine, 1.1 grms random 5-500 Hz
None required