Operation; Preliminary Controls; Water Flow Control Unit; Adjusting And Mounting Tools - lavina 20n-x User Manual

Table of Contents

Advertisement

Superabrasive 
4. OPERATION 
PRELIMINARY CONTROLS 
Inspect the working area as explained in the safety instructions. For wet use, fill the water tank with the electrical cable disconnected. 
Connect the vacuum extractor and ensure that the vacuum hose is clear and will easily follow the machine. Plug in the machine and 
make sure that the power cord is free to follow the working direction of the Lavina® X machine. 
 
WATER FLOW CONTROL UNIT 
The operator can direct water to be sprayed in the front 
(Fig.4.1) by positioning the lever in the horizontal position; 
the water will spray under the cover of the machine when 
the lever is in the vertical position (Fig.4.2). The flow 
regulating valve located on the tank (Fig.4.3) controls the 
water flow to the working area – in front of the machine or 
under the main head cover of the machine.
 
ADJUSTING AND MOUNTING TOOLS 
 
The Holder A41 in
LAVINA® X  can work with either 3 or 6 buffers, which will 
alter its range of motion. You can make the change after dismounting the 
holder as per the instructions in  TROUBLESHOOTING. 
In the Lavina 20‐X, the holder is initially mounted with 3 buffers. 
 
Mount the tools only after ensuring that there is enough diamond bond 
material left. Be sure that the plates are always clean before mounting. 
WARNING: Always secure the "Quickchange" pads with the security plate 
(Fig.4.4), and lock with the tool holder key (Fig.4.5). Diamond tools with Velcro are attached on three 9inch foam plates. The foam 
plates are mounted on the key lock (butterfly). Always use the tool holder key (Fig.5.3).
 
Figure 4.6
8.Potentiometer  controls the RPM of the grinding plates on a range of 300‐1100 rpm 
9. READY ON/OFF switch. Switching to ON puts the machine in standby mode. The switch lights to indicate this. 
Switching to OFF takes the machine out of standby. The light extinguishes to indicate this. 
The switch returns to its starting position after being released. 
10.STOP button stops the motor 
11. RUN button starts the motor 
12.Emergency button stops the motor in case of an emergency 
 
User Manual  
Original Language 
  
10 
12 
11 
Lavina® 20N‐X 
Figure 4.1
Figure 4.4
THE CONTROL BOARD 
 
1.Power cable plug 
2.Digital  Tachometer  Indicates  the  revolution  per  minute  of  the 
grinding plates (not the revolution per minute of the entire unit). 
3.Lamp cable gland 
4. Reset button resets the alarm of the inverter. Button lights 
blue when the inverter goes into alarm mode. 
5.Water pump switch Lights orange when the water pump is 
working. 
6.Power led lights green when the power is on  
7.Forward/Reverse switch Select forward for clockwise rotation 
of the grinding plates or reverse for counterclockwise rotation of 
the grinding plates (Recommended configuration). The preferred 
operating direction should be when the switch is in the forward 
position. The proper direction of rotation of the motor 
(counterclockwise) is indicated by an arrow on its cover.   
 
 
6/2017 
Figure 4.2
Figure 4.3
Figure 4.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents