VACUUM CONNECTION
A connection for a vacuum dust extractor is located on the carriage. The LAVINA® X machine does not include a vacuum dust
extractor. The customer must purchase the vacuum dust extractor separately. The hose of the vacuum extractor must be
Ø 50.8 mm and can be glided over the pipe. The vacuum dust extractor must be adapted for floor grinders and have a
minimum air displacement of 320m3/h with a negative vacuum of 21 kPa.
TECHNICAL DATA
Voltage/Hz
Amperage
Power
Tool holder rpm
Working width
Tool diameter (QC Plate)
Weight
Grinding pressure
Additional weight
Application
Vacuum hose port
Water tank capacity
Water feed
Cable length
Machine LxWxH
Packing LxWxH
VIBRATIONS
The vibrations of the machine are within the limits of directives and harmonized standards from the European Union when
the LAVINA® X is operated with the recommended tools and in normal conditions.
NOISE EMISSIONS
The noise emissions are within the limits of directives and harmonized standards from the European Union when the
LAVINA® X is operated with the recommended tools and in normal conditions. However, the operator must wear ear
protectors.
LABEL DATA
The data on the label provides the correct Voltage and kW (needed for operational purposes);
Weight (needed for transportation purposes); production year and serial number (needed for maintenance purposes).
CUSTOMER SERVICE
For customer assistance and technical support call your local distributor or call Superabrasive Inc. at
1‐800‐987‐8403 or visit us at: www.superabrasive.com , where you can download a copy of this manual.
2. SAFETY INSTRUCTIONS
RECOMMENDED USE
The LAVINA® X machine is
designed and manufactured to
grind and polish concrete, terrazzo, and natural stone floors. It
can be used for renovations as well as for polishing. The machine
is designed for dry or wet use. When using it dry, use a vacuum
of appropriate size. For more information, please refer to the
chapter on handling the
vacuum connection.
PROHIBITED USE
The machine MUST NOT be used:
For applications different from the ones stated in the General
Description chapter.
For not‐suitable materials.
User Manual
Original Language
Lavina® 20N‐X
1 or 3 ph x 200‐240V 50‐60Hz
Max 30 Amps
5,5 kW
300‐1100 rpm
510 mm
3x 225 mm
172 kg
91 kg
max 2x 22 kg
wet and dry
Yes
20 l
with pump (peripheral and front)
17.4 m
1350x540x1100 mm
53.1"x21.3"x43.3"
1150x730x1155 mm
45.2"x28.7"x45.5"
Lavina® 20N‐X
7,5 HP
20"
3x 9"
380 lbs
200 lbs
max 2x 48 lbs
5.2 gal
57 ft
In environments which:
‐
Possess risks of explosion
‐
Possess high concentration of powders or oil substances in the
air
‐
Possess risks of fire
‐
Feature inclement conditions.
‐
Possess electromagnetic radiation.
PREPARATION FOR WORK
Make sure that
You have closed the work area, so that no person unfamiliar with
operating the machine can enter the area.
The tool plate and tools are adjusted to the machine properly.
There are no missing parts of the machine.
The machine is in upright working position.
6