ELECTRICAL SYSTEM
Dust should not enter the control box, as it will destroy the contacts. Remove (blow out) any dust present.
The Lavina® 20N‐X 200‐240 Volt will automatically detect if the connection is based on single (L1, L2) or three phase (L1, L2, L3)
208‐240 Volt. The operator does not have to switch the machine; only connect to two phases or three phases.
SINGLE PHASE OR THREE PHASE CONNECTION
ONLY LAVINA® 20N‐X
For convenience, the machine is delivered with 2 different pigtails see (fig. 7.3); each is marked to identify usage. Mount a local plug
rated for 30 Amps to the wire. The yellow/green cable is the ground and should not be connected to a live terminal; grey, brown and
black are phases, see Fig.7.4 for the single‐phase connection and Fig.7.4 for the three‐phase