Frame R8I - ABB ACS800-37-0060-3 Hardware Manual

Acs800-37 series drives (55 to 2700 kw / 75 to 3000 hp)
Table of Contents

Advertisement

26

Frame R8i

The picture below shows the main components of a frame R8i drive with the doors
open.
4
2
3
14
1
13
The ACS800-37
5
8
6
7
9
12
11
10
No.
Description
1
Swing-out frame (see picture on page 27)
2
Supply unit controller (RDCU)
3
Inverter unit controller (RDCU)
4
Switch-disconnector*
5
Input contactor*
6
LCL filter
7
IGBT supply module
8
Intermediate DC link
9
Inverter module
10
Cooling fan for LCL filter
11
Cooling fan for IGBT supply module
12
Cooling fan for inverter module
13
Auxiliary voltage transformer (accessible by opening
the swing-out frame)
14
Auxiliary voltage circuitry (relays etc.)
*In larger drives, an air circuit breaker is used instead of the
switch-disconnector/contactor combination.