130
DC fuses
Notes:
• Larger fuses must not be used.
• Fuses from other manufacturers can be used if they meet the ratings.
• The recommended fuses are for branch circuit protection per NEC as required for
UL approval.
Drive type
400 V
ACS800-37-0060-3
ACS800-37-0510-3
ACS800-37-0640-3
ACS800-37-0770-3
ACS800-37-0960-3
ACS800-37-1070-3
ACS800-37-1430-3
ACS800-37-1810-3
500 V
ACS800-37-0070-5
ACS800-37-0610-5
ACS800-37-0780-5
ACS800-37-0870-5
ACS800-37-1160-5
ACS800-37-1330-5
ACS800-37-1820-5
ACS800-37-2200-5
690 V
ACS800-37-0170-7
ACS800-37-0540-7
ACS800-37-0790-7
ACS800-37-0870-7
ACS800-37-1160-7
ACS800-37-1330-7
ACS800-37-1510-7
ACS800-37-2320-7
ACS800-37-2780-7
ACS800-37-3310-7
Technical data
Qty
Bussmann
...
–
–
8
170M8552
8
170M8547
8
170M8547
12
170M8552
12
170M8547
16
170M8547
...
–
–
8
170M8552
8
170M8552
8
170M8547
12
170M8547
12
170M8547
16
170M8547
...
–
–
8
170M8646
8
170M8647
8
170M8647
12
170M8647
12
170M8647
16
170M8647
24
170M8647
24
170M8647
DC fuse information
IEC
Ferraz Shawmut
I
Bussmann
n
–
–
6.9URD3PV1000
1000 170M6215 1000
6.9URD33PA1250 1250 170M6216 1250
6.9URD33PA1250 1250 170M6216 1250
6.9URD3PV1000
1000 170M6215 1000
6.9URD33PA1250 1250 170M6216 1250
6.9URD33PA1250 1250 170M6216 1250
–
–
6.9URD3PV1000
1000 170M6215 1000
6.9URD3PV1000
1000 170M6215 1000
6.9URD33PA1250 1250 170M6216 1250
6.9URD33PA1250 1250 170M6216 1250
6.9URD33PA1250 1250 170M6216 1250
6.9URD33PA1250 1250 170M6216 1250
–
–
12URD73PA0700
700
170M8636
11URD73PA0800
800
170M8637
11URD73PA0800
800
170M8637
11URD73PA0800
800
170M8637
11URD73PA0800
800
170M8637
11URD73PA0800
800
170M8637
11URD73PA0800
800
170M8637
11URD73PA0800
800
170M8637
UL Recognized
I
n
–
–
–
–
–
–
700
800
800
800
800
800
800
800
PDM-184674-G5