4.0 - OPERATING INSTRUCTIONS

To arm the alarm press
receptacle. Arming is confirmed by a quick flash of the turn indicators.
The following functions are enabled:
a)
Module output (PINK wire, +A).
b)
Led output.
c)
Engine immobilizer.
d)
Door-lock control with pulse time selected during programming.
If the electronic key is used to arm the system, functions
enabled, whereas
without triggering an alarm.
When using the electronic key, there is also an entry delay countdown (approx.10
sec., LED ON steady) to allow the user to get into the car and disable the alarm
via the electronic key without generating an alarm.
4.2 - ARMING DELAY, SENSOR and COMFORT EXCLUSION, WINDOW-
An arming delay (approx. 45", LED ON steady) provides an exit time to leave
the vehicle without generating a false alarm. During the initial 25" of the arming
delay countdown, external sensors can be excluded and window roll-up
stopped by pressing button 2 on the remote control (NB: window roll-up
requires installation of module 2344 or the vehicle must be equipped with
Comfort System). A quick flash of the turn indicators will confirm exclusion of
sensors/window-up stop/comfort feature.
Sensor exclusion is bound to a single alarm activation cycle.

4.3 - SIREN SOUND EXCLUSION WHEN ARMING

This function allows arming the alarm system without any siren sound in case
of an alarm event. To exclude the siren,
!
Turn ignition key "ON".
!
The LED will turn ON for approx. 0,5 sec.
!
While the LED is ON, press remote control button 2.
!
The LED will turn OFF.
!
To reactivate acoustic signaling, simply arm and disarm the system.
Siren sound exclusion is bound to each single arming cycle.

4.4 - TOTAL ARMING AFTER ARMING DELAY

After the 45" arming delay, the alarm system will be fully armed and ready to
detect any alarm condition.The LED will flash as follows to minimise power
consumption:
LED ON :

USER MANUAL

4.1 ALARM ARMING

remote control
d)
will be disabled to provide time to exit the vehicle
UP STOP
200ms -
LED OFF :
button 1 or touch the electronic key to its
proceed as follows:
2sec
a) b)
,
and
c)
will be
PAGE 5