Cylinder unit

Safety information
(Before installing a cylinder unit, please read this manual thoroughly to ensure that you know how to safely and efficiently
install a new appliance.)
WARNING
f The installation must be done by the manufacturer or its service agent or a qualified person in order to avoid a hazard.
- Installation by an unqualified person may cause a water leakage, electric shock or fire and so on.
f The electric work must be done by service agent or qualified persons according to national wiring regulations and use
only rated cable.
- Use certified power cable in the market suggested here and do electric work according to installation manual
otherwise, electric shock or fire may occur.
f Install the outdoor unit correctly according to the installation manual.
- An incorrect installation may cause a water leakage, electric shock or fire and so on.
f Manufacturer is not responsible for accidents due to incorrect installation.
f Use certified parts in the market and supplied parts from the factory.
- All wiring, components and materials to be procured on the site must comply with the applicable local and national
codes. If you don't use the certified parts and tools, it can cause trouble to the air conditioner and bring into injury.
f Install the cylinder unit on a hard and even place that can support its weight.
- If the place cannot support its weight, the outdoor unit may fall down and it may cause injury.
f Fix the outdoor unit securely on foundation as it can fall over strong wind or earthquake.
- If the outdoor unit is not properly fixed, it turns over and accidents may occur.
f Secure power cable with a conduit, which is accessory part for cylinder unit, not to be pulled out by external force.
- If fixing is incomplete, it can cause trouble with a heat generation, electric shock or fire and so on.
f The disinfection function field settings must be configured by the installer according to local laws and regulations.
f Attach the service cover to the cylinder unit and outdoor unit securely without any gaps. If there are any gaps, there is
potential risk of fire or electric shock due to dust or water.
f Make sure to earth the unit. Do not connect the earth wire to the gas pipe or water pipe, lighting rod, surge absorber, or
telephone earth wire. If earthing is not complete, It may cause an electric shock or fire.
f The water heater should be fitted level on a hard surface with sufficient load strength to take the full weight of the
cylinder. Adjustable feet are fitted to ensure the unit can be adjusted to a level position. There is no limitations regarding
the fitting distance from walls etc., but it is strongly recommended to ensure easy access to all pipe fittings etc. There
should be at least 80 cm of free space in front of the water heater to ensure easy access for servicing and maintenance.
f If the water heater is in danger of being exposed to frost while not operating under electric power, the unit must be
drained to avoid damage. Make sure the electric power is turned off before draining, otherwise the heating elements can
be damaged and the warranty is void. Draining instructions, see "Commissioning"
40
EHS mono_RC***MHXGA_IM_E_34411A(3).indd 40
• If you don't follow the safety precautions, you may get the risk of serious wound or death.