Cylinder unit
Description
Dimensions
Connections
Weight
Max. Water temperature
Hot water capacity BS EN 12897 (60°C)
Heating times BS EN 12897 (15~60°C)
Heating power of coil BS EN 12897
Other
max design
Model
pressure
NH200CHXEA
8 bar
NH300CHXEA
8 bar
Temperature rise is from 15 to 60°C. Coil heating performance based on a primary flow rate of 15 l/min. at 80°C. (EN12897)
46
EHS mono_RC***MHXGA_IM_E_34411A(3).indd 46
Vessel
Net
Packing
Cold water inlet(city water)
Flow from Heat Pump
Return to Heat Pump
Sensor pocket(s)
Weight empty
Max weight full
Packaging
Adjustable legs
Operating pressure
CW feed & coil
primary heater
cw in 3bar, coil 2.5bar
cw in 3bar, coil 2.5bar
Unit
NH200CHXEA
mm
585 x 1130
mm
692 x 702 x 1200
mm
800 x 900 x 1600
mm
ø22mm pipe
mm
ø28mm pipe
mm
ø28mm pipe
mm
ø8.05 mm inside, 1/2" thread
kg
68
kg
260
°C
184
min
31.68
kW
17.98
-
pcs
Pressure drop
Temp./pressure
relief valve
0,03bar
90-95°C/ 10bar
0,03bar
90-95°C/ 10bar
Standard
NH300CHXEA
585 x 1580
692 x 702 x 1600
800 x 900 x 2050
ø22mm pipe
ø28mm pipe
ø28mm pipe
80
359
70
229
45
25.71
Eco Foam - PUF
3
Safety valve
Exp. Vessel
Pressure/ conn.
capacity
8bar/ 15mm - 1/2"
12 L
8bar/ 15mm - 1/2"
18 L