Cylinder unit
Wiring diagram
• Turn on the cylinder unit and outdoor unit after completing electric wiring works.
• Do not disassemble the wirings out of the unit while the unit is operating.
CAUTION
• Circuit breaker shall be installed for safety and maintenance .
• Fill the cylinder unit with water before turning on electric power.
f Make sure of an earthing.
- Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. If earthing is incomplete,
electric shock or fire may occur.
66T
1
2
59T
Electrical connections – Technical Data:
Electric element
Adjustable
Thermostat
Safety cut-off
Electric central
Electric immersion heater shall comply with EN 60335-2-73
48
EHS mono_RC***MHXGA_IM_E_34411A(3).indd 48
40.4
Date code
Cal lot No.
59T 4117
ø5.56
2 holes
42.52
50.8
63.5
2.6 kW 230V 1 phase, 1 1/4" connection with O-ring seal
Electric output can be reduced by cutting one bridge on the element.
40~70°C (preset 60°C)
85°C
Internally connected from factory. Splash proof IP21.
Wiring diagram
1
2
Outer casing
2012-11-26 오후 3:02:03