solar storage solar cylinder idra ds installation ManUal User ManUal...
Page 2
MODEL CODE gned to give dependable and safe service and to provide comfort in the home for many years to come. Arrange for BERETTA IDRA DS 200 20001224 your solar storage cylinder to be serviced regularly BERETTA IDRA DS 300...
GENERAL general safety inforMation PrecaUtions The operation of any appliance that uses electrical power Check that the product is complete, undamaged and demands that a number of fundamental safety precautions as ordered as soon as you receive it. Report any di- be respected.
IDRA DS Data plate This lists the technical specifications and performance of the product. Beretta Caldaie Via Risorgimento, 1323900 Lecco (LC) T067659ED02 SOLARBOILER SOLAR STORAGE CYLINDER Modell Herstell. Nr.
GENERAL Water circUit TYPICAL WATER SYSTEM SCHEMATIC Solar regulator MI Dir MI Mix RI Dir RI Mix °C Boiler Water control system Solar collector Mixer valve Collector temperature sensor socket Domestic hot water outlet Manual bleed valve Domestic cold water inlet Vent cock Mixed central heating flow MI Mix...
GENERAL location of sensors storage cylinders are equipped with dedicated sockets for the storage cylinder TEMPERATURE GAUGE IDRA DS or TEMPERATURE SENSOR. The installer is responsible for making all necessary connections to the boiler and solar collectors. Installers must use their expertise to ensure proper installation and functioning in compliance with all applicable legislation.
GENERAL overall diMensions and Water fittings 200 - 430 IDRA DS EAF (SB) (*) Cable routing IDRA DS DESCRIPTION Domestic hot water outlet 1” F Ø Outlet from boiler 1” F Ø Return to boiler 1” F Ø Outlet from solar collector 1”...
Page 11
GENERAL 300 - 550 IDRA DS EAF (SB) (*) Cable routing IDRA DS DESCRIPTION Domestic hot water outlet 1” F Ø Outlet from boiler 1” F Ø Return to boiler 1” F Ø Outlet from solar collector 1” M Ø Return to solar collector 1”...
Page 12
GENERAL 750 - 1000 IDRA DS EAF (SB) (*) Cable routing IDRA DS DESCRIPTION 1000 Domestic hot water outlet 1 ¼” M Ø Outlet from boiler 1” F Ø Return to boiler 1” F Ø Outlet from solar collector 1” M Ø...
INSTALLER 10 UnPacking tHe ProdUct MODELS IDRA DS 200 to 550 The second anode for installation instead of the in- storage cylinders are delivered in a single IDRA DS spection flange is supplied separately and must be package, protected by a cardboard box on a wooden pal- fitted by the installer.
INSTALLER 11 Handling Adjust the feet to ensure that the storage cylinder is per- MODELS IDRA DS 200 to 550 fectly level. Make sure that any lifting equipment is of adequate capa- city to lift and move the storage cylinder.
Page 15
INSTALLER If suitable equipment is not on hand to lift the storage cylin- The casing and insulation can be removed to facilitate ac- der off the pallet using the eyebolt, proceed as follows. cess into the place of installation. To do so, proceed as - Place a platform of about half the height of the pallet near follows.
INSTALLER 12 Place of installation 13 installation in older systeMs and systeMs storage cylinders can be installed in any IDRA DS reqUiring Modernisation room where there is no specific requirement for an electri- cal protection rating higher than IP X0D. When installing storage cylinders in old sy- IDRA DS...
TECHNICAL ASSISTANCE CENTRE 14 PUtting into service 15 teMPorary sHUtdoWn It is essential to perform the following checks before star- If you are going away for a short period of time like a we- ting up or testing the functioning of the storage cylinder. In ekend or a short holiday, etc., and outdoor temperatures particular, check that: are going to remain above ZERO, proceed as follows.
INTERNAL CLEANING - Fill the storage cylinder’s DHW (secondary circuit) and MODELS IDRA DS 200 to 550 check that there are no leaks from any of the seals. - Check the performance of the storage cylinder. Removing and checking the magnesium anode - Remove the plug (1) and insulation (2), and use a sui- table wrench to unscrew the anode holder (3).
Page 19
TECHNICAL ASSISTANCE CENTRE MODELS IDRA DS 750 - 1000 Removing and checking the second magnesium anode - Remove the flange cover (5) and use a suitable wrench to unscrew the anode holder (6). Removing and checking the first magnesium anode If the magnesium anode is fitted in the top of the storage - Check the magnesium anode for wear and replace it if cylinder, remove the cover (1) and insulation (2), and use a...
TECHNICAL ASSISTANCE CENTRE 19 recycling and disPosal At the end of its useful working life, do not abandon the storage cylinder in the environment, but dispose of it through the proper channels in accordance with applicable legislation. 20 troUblesHooting SUPPLEMENTARY HEATING CIRCUIT FAULT CAUSE SOLUTION...
END USER END USER INSTRUCTIONS Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information. 21 start-UP 22 teMPorary sHUtdoWn The storage cylinder must be put into service for the first To reduce impact on the environment and save energy, time by personnel from the manufacturer’s Technical Assi- before leaving for the weekend or a short break, etc., pro- stance Centre.
Page 24
Via Risorgimento, 13 - 23900 Lecco (LC) - Italy Customer Service 199.13.31.31* www.berettaclima.it The manufacturer strives to continuously improve all products. Appearance, dimensions, technical specifications, standard equipment and accessories are therefore liable to modification without notice.
Need help?
Do you have a question about the IDRA DS 200 and is the answer not in the manual?
Questions and answers