Peak supply
current (during
transmission
slot)
NOTE
1)
1.
Power control level PCL 5.
2)
2.
Power control level PCL 0.
3.
Under the EGSM900 spectrum,the power of 1Rx and 4Tx has been reduced.
5.4.

Current Consumption

The values of current consumption are shown as below.
Table 30: The Module Current Consumption
Condition
Voice Call
GSM850
EGSM900
DCS1800
PCS1900
GPRS Data
M35_User_Manual
DATA mode, GPRS (4Rx,1Tx)
1)
GSM850/EGSM900
2)
DCS1800/PCS1900
DATA mode, GPRS (1Rx,4Tx)
1)
GSM850/EGSM900
2)
DCS1800/PCS1900
Maximum power control level
on GSM850 and EGSM900.
Current Consumption
@power level #5 <300mA, Typical 223mA
@power level #12, Typical 83mA
@power level #19, Typical 62mA
@power level #5 <300mA, Typical 219mA
@power level #12, Typical 83mA
@power level #19, Typical 63mA
@power level #0 <250mA, Typical 153mA
@power level #7, Typical 73mA
@power level #15, Typical 60mA
@power level #0 <250mA, Typical 151mA
@power level #7, Typical 76mA
@power level #15, Typical 61mA
Confidential / Released
GSM/GPRS Module Series
M35 User Manual
217/234
172/170
458/485
462/439
1.6
2
mA
mA
mA
mA
A
67 / 85