10 Technical Data
BLS3000
Measuring element
Reed switch
Measuring ranges
L0 = max. 1000 mm, LM: see name plate
Display
4-digit 14-segment LED display, red, digit height 9 mm
Transistor switching outputs PNP
1 or 2 x NO/NC function (programmable), adjustable switching time delay
0 ... 50 s
Resolution
5 mm
Ambient temperature range
-20 ... +70 °C / -4 ... +158 °F
Media temperature range
-25 ... +80 °C / -13 ... +176 °F
Storage temperature range
-30 ... +80 °C / -22 ... +176 °F
Process connection
G ½" M, G ¾" M, G 1" M, M20x1,5 M, ½" NPT M, ¾" NPT M,
1" NPT M, 1¼" NPT M
2)
Protection system
/ class
IP65, IP67; UL-Type 1,4X,6 / III
Electrical connection
Plug M12x1 mm, 4/5/8-pin (depending on output code),
Power supply
15... 32 V DC /relay-output: 20-32 V DC
1)
Approvals
cULus
For further technical data and options please refer to the data sheets
1)
Conditions of use: 60°C max. ambient, power supply max. 28 V DC
2)
The stated ingress protection only applies when plugged in using mating connectors that have the appropriate
ingress protection
Operating and display elements/Dimensions
41 (1.598)
M12x1 Connector
hex 27
(1.063)
G1/2" Shown
17.80 (0.701)
12
Dimensions (example) in mm (inch)
1
2
Item 1: LEDs
AL
(red) – Alarm
S1
(red) – switching point 1
S2
(red) – switching point 2
Item 2: keys
For functions refer to chapter 7
"Programming" on page 5.

Operating Instructions ............................................................................................................ 2

 
1
Intended Applications ................................................................................................... 2
 
2
Safety Instructions ......................................................................................................... 3
 
3
Standards ....................................................................................................................... 3
 
4
Warranty/Guarantee ....................................................................................................... 3
 
5
Installation ...................................................................................................................... 3
 
6
Commissioning/Operation ............................................................................................ 5
 
O
7
Programming .................................................................................................................. 5
 
7.1
Parameters ............................................................................................................. 6
 
7.2
Menu Structure ....................................................................................................... 8
 
8
Maintenance/Cleaning ................................................................................................. 11
 
9
Decommissioning ........................................................................................................ 11
10
Technical Data ............................................................................................................... 12
Barksdale Inc.
3211 Fruitland Avenue
Los Angeles, CA 90058-0843
U.S.A.
Phone:
(323) 589-6181
Fax:
(323) 589-3463
e-mail:
sales@barksdale.com
www.barksdale.com
Operating Instructions
Dual Level Switch BLS3000
Art. no. 923-2159
Index A, 19.08.2016
Software-Version: 1.4 and higher
Specifications are subject to changes
without notice!
Barksdale GmbH
Dorn-Assenheimer Straße 27
D-61203 Reichelsheim
Phone:
+49 (6035) 949-0
Fax:
+49 (6035) 949-111 und 949-113
e-mail:
info@barksdale.de
www.barksdale.de
 
 
 
 
 
 
 
 
 
 
 
 
1

Advertisement

loading

Summary of Contents for Barksdale BLS3000

  • Page 1: Operating Instructions

    Operating Instructions 10 Technical Data Dual Level Switch BLS3000 BLS3000 Measuring element Reed switch Measuring ranges L0 = max. 1000 mm, LM: see name plate Display 4-digit 14-segment LED display, red, digit height 9 mm Transistor switching outputs PNP 1 or 2 x NO/NC function (programmable), adjustable switching time delay 0 ...
  • Page 2: Installation

    The safety instructions are intended to protect the user from dangerous situations and/or material No liability is assumed for any damage resulting therefrom, or any consequential damage. damage. Refer to Barksdale "Standard Terms and Conditions". In the operating instructions the seriousness of the potential risk is designated by the following Installation...
  • Page 3: Commissioning, Operation

    The mounting situation (immersion depth, probe length, operating conditions) largely determines the Commissioning/Operation measuring accuracy of the level switch to be achieved. The level switch may only be commissioned and operated by authorized staff. CAUTION CAUTION The following notes must absolutely be observed: Do not put the switch into operation when the switch itself or the connection cable is damaged.
  • Page 4 7.1 Parameters Parameter 14-segment display Description Parameter 14-segment display Description ASP** Analog start value SP1/SP2* Hysteresis function: switching point of solid state contact AEP** Analog end value FH1/FH2* Window function: window High solid state contact dPA** Damping of analog output rP1/rP2* Hysteresis function: hysteresis of solid state contact ErS.A**...
  • Page 5: Menu Structure

    7.2 Menu Structure Factory setting Factory setting Display Unit dr2* Hysteresis delay, output 2 SP1 / FH1 Output 1 Off - Hno - Switching point 1 0... x % Hnc - Fno - rP1 / FL1 Hysteresis 1 0... x % Output 2 Off - Hno - Hnc - Fno -...
  • Page 6: Software Lock

    only models with 2nd switching contact Factory only models with analog output setting no automatic conversion If the unit and/or the display of the measured values are changed all parameters for switching points or analog output must be checked and adjusted as required. AEP** Analog end max ...