Page 3
AMS 301 The main menus Device information - main menu AMS 301i 120 Leuze electronic This menu item contains detailed information on • Device model, GmbH & Co. KG • Manufacturer, SW: V 1.3.0 HW:1 • Software and hardware version, SN: ----------------------- •...
Notice! The Declaration of Conformity for these devices can be requested from the manufacturer. The manufacturer of the product, Leuze electronic GmbH + Co. KG in D-73277 Owen/Teck, possesses a certified quality assurance system in accordance with ISO 9001. LISTED...
With the AMS 3xxi product series, Leuze electronic makes available a range of internation- ally relevant interfaces. Note that each interface version listed below corresponds to a different AMS 3xxi model.
Leuze electronic GmbH + Co. KG is not liable for damages caused by improper use. Read the technical description before commissioning the device. Knowledge of this technical description is an element of proper use.
The device must not be tampered with and must not be changed in any way. The device must not be opened. There are no user-serviceable parts inside. Repairs must only be performed by Leuze electronic GmbH + Co. KG. Competent persons Connection, mounting, commissioning and adjustment of the device must only be carried out by competent persons.
Safety Disclaimer Leuze electronic GmbH + Co. KG is not liable in the following cases: • The device is not being used properly. • Reasonably foreseeable misuse is not taken into account. • Mounting and electrical connection are not properly performed.
Page 12
Affix the laser information and warning signs so that they are legible without exposing the reader to the laser radiation of the device or other optical radiation. A Laser aperture B Laser warning sign C Laser information sign with laser parameters Figure 2.1: Laser apertures, laser warning signs Leuze electronic 301i...
Fast commissioning / operating principle Fast commissioning / operating principle Notice! Below, you will find a short description for the initial commissioning of the AMS 301i. Detailed explanations for the listed points can be found throughout the handbook. Mounting the AMS...
The transmission parameters are listed above the menu structure or on the fold-out page at the end of the technical description. The parameters can be adjusted after activation of parameter enabling. Detailed information can be found in chapter 9. 301i Leuze electronic...
2 acc. to EN 60825-1, CDRH Interfaces RS 485 / baud rate in kbit/s 9.6 / 19.2 / 38.4 / 57.6 / 115.2 Operating and display elements Keyboard 4 buttons Display monochromatic graphical display, 128 x 64 pixels 2 LEDs, two-colored Leuze electronic 301i...
Page 17
A 100% prevention of the formation of condensation cannot be guaran- teed due to the limited heating capacity of the AMS 301i. This is a Class A product. In a domestic environment this product may cause radio interference, in which case the operator may be required to take adequate measures.
Specifications 4.1.2 Dimensioned drawing AMS 301i M5 screw for alignment Knurled nut with WAF4 hexagon socket and M5 nut for securing Optical axis Zero point of the distance to be measured Figure 4.1: Dimensioned drawing AMS 301 Leuze electronic 301i...
Device name plate using the AMS 300 as an example Notice! Please note that the shown name plate is for illustration purposes only; the contents do not correspond to the original. Save the original packaging for later storage or shipping. Leuze electronic 301i...
Installation and mounting If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office. Observe the applicable local regulations when disposing of the packaging materials. Mounting the AMS 301i M5 screw for align-...
Page 22
WAF4 hexagon socket ("B" in figure 5.2). Knurled nut and nut must not be tightened until alignment has been completed. Attention! The device must not be opened. Failure to comply will render the guarantee void. Warranted features cannot be guaranteed after the device has been opened. Leuze electronic 301i...
Optional mounting bracket A mounting bracket for mounting the AMS 301i on a flat, horizontal surface is available as an optional accessory. Type designation: MW OMS/AMS 01 Part no.: 50107255 Laser beam Figure 5.3: Optional mounting bracket 301i Leuze electronic...
301i devices with respect to one another can be calculated as a function of the maximum measurement distance. To define the minimum parallel spacing between two AMS 301i, it is necessary to distinguish between three different arrangements of AMS 301i and reflectors.
301i do not interfere with one another. Depending on the size of the used reflector, the DDLS can be mounted with a minimum parallel spacing of 100mm to the AMS 301i. The parallel spacing is independent of the distance. 301i...
AMS 301i… and the deflection mirror as well as between the mirror and the reflector. Use the M5 screws to mount the deflector unit. Secure the screws with a toothed lock washer to protect against loosening caused by vibrations.
Installation and mounting 5.3.2 Dimensioned drawing of US AMS 01 deflector unit Laser beam Figure 5.6: Dimensioned drawing of US AMS 01 deflector unit 301i Leuze electronic...
Height of the spring in non-preloaded state A Mirror Figure 5.7: Photo and dimensioned drawing of the US 1 OMS deflector unit Alignment of the laser light spot on the reflector is performed as described in chapter 5.2. Leuze electronic 301i...
301i measures distances against a reflective tape specified by Leuze electronic. All provided specifications for the AMS 301i, such as the operating range or accuracy, can only be achieved with the reflective tape specified by Leuze electronic. The reflective tapes are available as adhesive tapes, affixed to a metal plate and with an integrated heater especially for use at low temperatures.
Do not use any agents that act with a grinding effect. A conventional household Cleaning detergent can be used as a cleaning agent. Rinse with clear water and dry the surface. Storing the reflector Store in a cool and dry place. Leuze electronic 301i...
Dimensioned drawing of reflective tape on a metal plate Always align the TOP marking with the AMS connections! (chapter 6.4.2) Figure 6.1: Dimensioned drawing of reflectors Part Reflective tape (mm) Reflector plate (mm) Reflective tape 200x200-M Reflective tape 500x500-M Reflective tape 914x914-M 301i Leuze electronic...
Do not use any agents that act with a grinding effect. A conventional house- Cleaning hold detergent can be used as a cleaning agent. Rinse with clear water and dry the surface. Storing the reflector Store in a cool and dry place. Leuze electronic 301i...
Attention! The reflector sizes shown below are a recommendation from Leuze electronic for on-vehicle mounting of the AMS 301i. For stationary mounting of the AMS 301i, a smaller reflector is generally sufficient for all measurement distances. On the basis of the system planning and design, always check whether mechanical travel tolerances may require the use of a reflector larger than that which is recommended.
For this purpose, use the alignment elements provided on the AMS 301i… (see chapter 5.2 "Mounting the AMS 301i"). If necessary, remove the protective foil from the reflector.
Page 36
Reflective tapes …-S and …-M Pitch approx. 1° Direct reflection from the triad structure Deflected surface reflection due to the pitch of the reflective tape Figure 6.3: Reflector mounting Pitch approx. 1° Spacer sleeves Figure 6.4: Pitch of the reflector Leuze electronic 301i...
Page 37
Pitch approx. 1° Direct reflection from the triad structure Deflected surface reflection due to the pitch of the reflective tape Figure 6.5: Mounting of heated reflectors Pitch approx. 1° Spacer sleeves Figure 6.6: Pitch of the heated reflector 301i Leuze electronic...
Notice! Reliable function of the AMS 301i and, thus, max. operating range and accuracy can only be achieved with the reflective tape specified by Leuze electronic. No function can be guar- anteed if other reflectors are used! Leuze electronic 301i...
M12 connector M12 socket (B-coded) (B-coded) PWR / IOs M12 connector (A-coded) Leuze SERVICE M12 socket (A-coded) Figure 7.1: Connections of the AMS 301 Safety notices for the electrical connection Attention! Before connecting the device, be sure that the supply voltage agrees with the value printed on the name plate.
Data RS 485 B (-) GND 485 GND 485 Data reference potential RS 485 A Data RS 485 A (+) RS 485 B Functional earth M12 connector (B-coded) Thread Shield Shield Table 7.2: RS 485 BUS IN pin assignment Leuze electronic 301i...
Transmission line RS 232/service data Voltage supply 0VDC RS232-RX Receiving line RS 232/service data Not used RS232-RX M12 socket Thread Functional earth (housing) (A-coded) Table 7.4: Service pin assignments Notice! The service interface is designed only for use by Leuze electronic! 301i Leuze electronic...
Display and control panel AMS 301i Display and control panel AMS 301i Structure of the control panel Status display Bus/interface info Bar graph Distance measurement value Control buttons Figure 8.1: Structure of the control panel using the AMS 304 PROFIBUS device variant as an example...
Page 43
Display and control panel AMS 301i Warning - laser prefailure message: Laser diode old, device still functional, exchange or have repaired. Warning - temperature monitoring: Permissible internal device temperature exceeded / not met. Plausibility error: Implausible measurement value. Possible causes: light beam interruption, outside of measurement range, permissible internal device temperature considerably exceeded or traverse rate >10m/s.
Display and control panel AMS 301i 8.2.2 LED status displays PWR LED Device OFF - No supply voltage Flashing green Power LED flashes green - No measurement value output - Voltage connected - Self test running - Initialization running - Boot process running...
Display and control panel AMS 301i 8.2.3 Control buttons Navigate upward/laterally. Down Navigate downward/laterally. Exit menu item. ENTER Confirm/enter value, change menu levels. Navigating within the menus The menus within a level are selected with the up/down buttons The selected menu item is activated with the enter button Press the ESC button to move up one menu level.
Display and control panel AMS 301i Menu description 8.3.1 The main menus After voltage has been applied to the laser, device information is displayed for several seconds. The display then shows the measurement window with all status information. Device information - main menu...
Display and control panel AMS 301i Notice! The rear cover of this manual includes a fold-out page with the complete menu structure. It describes the menu items in brief. 8.3.2 Parameter menu Parameter handling submenu The following functions can be called up in the Parameter handling submenu: •...
Page 48
Display and control panel AMS 301i Table 8.2: RS 485 submenu Level 3 Level 4 Level 5 Selection/configuration option Standard Description Position resolu- 0.01mm / 0.1mm / 1mm / 10mm / free resolution 0.1mm tion The measurement value can be displayed in these resolutions.
Page 49
Display and control panel AMS 301i I/O submenu Table 8.4: I/O submenu Level 3 Level 4 Level 5 Selection/configuration option Standard Description I/O 1 Port config- Input/Output Output uration Defines whether I/O 1 functions as an output or input. Switching...
Service RS232 Baud rate 57.6kbit/s / 115.2kbit/s 115.2kbit/s The service interface is only available to Leuze internally. Format 8,e,1 / 8,n,1 8,n,1 The service interface is only available to Leuze internally.
Display and control panel AMS 301i 8.3.4 Service menu Service Status messages Diagnostics Expanded diagnostics A more detailed description of the individual functions can be found in chapter 10. Operation Described here is an operating process using parameter enabling as an example.
Page 52
Parameter entry on the AMS 301i can be protected with a four-digit numerical password. With the AMS 301i, the password is entered via the display. If parameter enabling has been activated after successfully entering the password, parameters can be changed via the display.
(FE) RS 485 B Data RS 485 B (-) GND 485 GND 485 Data reference potential RS 485 A Data RS 485 A (+) RS 485 B Functional earth M12 connector Thread Shield Functional earth (housing) (B-coded) 301i Leuze electronic...
To do this proceed as follows: Activate parameter enabling. Select the RS485 submenu. Select the address menu item. Select the RS 485 address of the AMS 301i to be between 0 and 15. Deactivate parameter enabling. Leuze electronic 301i...
Possible address entry from 0 to 15. The address used must be set on the AMS 301i via the display. Bit 0 = LSB, Bit 3 = MSB Byte 1: Command = Data request to the AMS 301i. 301i Leuze electronic...
Page 56
The XOR checksum is entered by the sender (control) in the query protocol and checked by the receiver (AMS 301i). A protocol is correctly transmitted when the XOR checksum of the transmitter is equal to the XOR checksum of the receiver. If the XOR comparison is...
Page 57
(control). A protocol is correctly transmitted when the XOR checksum of the transmitter is equal to the XOR checksum of the receiver. If the XOR comparison is negative (different checksum), the protocol is discarded by the control or the control will output an error message. 301i Leuze electronic...
Diagnostics and troubleshooting Diagnostics and troubleshooting 10.1 Service and diagnostics in the display of the AMS 301i In the main menu of the AMS 301i, expanded "Diagnostics" can be called up under the Service heading. Service Status messages Diagnostics Expanded diagnostics...
Use the up/down buttons to scroll in the bottom half between various displays. The contents of the scrollable pages are intended solely for Leuze for internal evaluation. The diagnostics have no influence on the communication to the host interface and can be activated during operation of the AMS 301i.
Laser diode prefailure message Send in device at next possible opportunity to have laser diode replaced. Have replacement device Laser diode warning ready. Indicates an uncorrectable error in the hardware Send in device for repair. Hardware error. Leuze electronic 301i...
Page 61
Customer data (please complete) Device type: Company: Contact partner / department: Phone (direct): Fax: Street / No: ZIP code/City: Country: Leuze Service fax number: +49 7021 573 - 199 301i Leuze electronic...
Contact your Leuze distributor or service organization should repairs be required. The addresses can be found on the inside of the cover and on the back. Notice! When sending the laser measurement systems to Leuze electronic for repair, please provide an accurate description of the error. 12.3...
Page 69
Overview of reflector types ....60 Fast commissioning ....11 301i Leuze electronic...
Page 71
Menu structure AMS 301 Level 1 Level 2 Level 3 Level 4 Level 5 Selection/configuration option Detailed information on : selection : selection : selection : selection : selection : selection : back : back : back : back : activate : back Device information page 41...
Page 72
57.6kbit/s / 115.2kbit/s Format 8,e,1 / 8,n,1 Language selection Deutsch / English / Español / Français / Italiano page 45 Service Status messages page 46 Diagnostics Exclusively for service purposes by Leuze electronic Expanded diagnostics Exclusively for service purposes by Leuze electronic...