Operating menu

Intermediate height

Navigation
Prerequisite
Description
User entry
Factory setting
Additional information
Table mode
Navigation
Prerequisite
Description
Selection
Factory setting
*
Visibility depends on order options or device settings
168
 Setup → Advanced setup → Linearization → Intermed. height
Linearization type (→  164) has one of the following values:
• Pyramid bottom
• Conical bottom
• Angled bottom
Specify intermediate height H.
0 to 200 m
0 m
H
Intermediate height
The unit is defined in the Distance unit parameter (→  133).
 Setup → Advanced setup → Linearization → Table mode
Linearization type (→  164) = Table
Select editing mode of the linearization table.
• Manual
*
• Semiautomatic
• Clear table
• Sort table
Manual
Levelflex FMP51, FMP52, FMP54 PROFIBUS PA
H
0%
A0013264