Error No.
Error type
220101F9
Warning
220101FA
Warning
220101FC
Warning
22010226
Warning
22010227
Warning
22010228
Warning
22010231
Warning
22010232
Warning
22010233
Warning
22010234
Warning
22010240
Warning
22010241
Warning
22010242
Warning
22010243
Warning
22010244
Warning
22010245
Warning
22010250
Warning
2201xxxx
Warning
23010001
Warning
23010003
Warning
23010005
Warning
23010007
Warning
23010009
Warning
2301000B
Warning
2301000D
Warning
Wieland Electric GmbH | BA000966 | 07/2016 (Rev. C)
Logbook message
Error in system configuration
Error in system configuration
Error in system configuration
Error in system configuration
Error in system configuration
Error in system configuration
Pulse period 0 must have pulse
length 0.
Pulse length must be <= pulse peri-
od/2.
Impermissible test period (permissib-
le: 0,40,200,400,600,800,1000).
Pulse length must be multiple of 4
and in range from 4 to 100ms
Maximum count of function blocks
or mapping exceeded
The number of IO modules is diffe-
rent in the configuration
The number of Gateway modules is
different in the configuration
The major version of the CPU modu-
le and project file differs.
The major version of the IO module
and project file differs.
The major version of the gateway
module and project file differs.
function blocks for presses are not
supported by this device
Error in the configuration
Processing error at I1/I2
Processing error at I3/I4
Processing error at I5/I6
Processing error at I7/I8
Processing error at I9/I10
Processing error at I11/I12
Processing error at I13/I14
System behavior
Remedy
Configuration requi-
Reload system confi-
red
guration
Configuration requi-
Reload system confi-
red
guration
Configuration requi-
Reload system confi-
red
guration
Configuration requi-
Reload system confi-
red
guration
Configuration requi-
Reload system confi-
red
guration
Configuration requi-
Reload system confi-
red
guration
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
Configuration requi-
Change system con-
red
figuration and reload
System continues to
run
System continues to
run
System continues to
run
System continues to
run
System continues to
run
System continues to
run
System continues to
run