Extron electronics DTP T USW 223 User Manual page 9

Three input switcher with integrated dtp transmitter
Table of Contents

Advertisement

c
Audio input port — If desired, plug an analog audio input into the switching
transmitter via this stereo mini jack connector. Analog audio is not embedded into
the digital video signal.
NOTES:
The analog audio input on this connector is
in addition to the digital audio that may be
embedded in the HDMI inputs. See the figure
at right to identify the connector tip, ring, and
sleeve when you are making connections for the
switching transmitter from existing audio cables.
A mono audio connector consists of the tip and
sleeve. A stereo audio connector consists of the
tip, ring, and sleeve.
If you have removed the ground jumpers (see
page 19) because of ground potential differences, the DTP T USW 233 cannot
extend analog audio. The connected receiver outputs no analog audio.
The analog audio can be assigned to a specific input or set to be always
output (see
Assign analog audio
d
Over DTP RS-232 and IR port — Plug a serial RS-232 signal, a
modulated IR signal, or both into this 3.5 mm, 5-pole captive screw
connector for bidirectional RS-232 and IR communication (see see
RS-232 connector wiring
e
DTP Output RJ-45 port — Plug one end of a TP cable to this
RJ-45 female jack on the switching transmitter. Plug the opposite end of
this cable is into the DTP Input RJ-45 connector on a compatible receiver
(see
TP cable termination and recommendations
properly wire the RJ-45 connector and for detailed NOTES).
Do not connect this device to a telecommunications or computer
ATTENTION:
data network.
Signal LED — Lights when the unit is outputting a TMDS clock signal on the DTP output.
Link LED — Indicates a valid link is established between the units on the DTP cable.
f
Remote Contact port — If desired, for contact closure control, plug a
locally-contructed contact closure device into this 3.5 mm, 4-pole captive
screw port. Momentarily short the pin for the desired input (1, 2, or 3) to G to
select that input. To force an input to be always selected, leave the short in
place.
NOTES:
Contact closure control overrides front panel input selections.
For contact closure control, auto switch mode must be off (see
switch mode
on page 11).
Disconnecting the Ground
SIS commands on page 15).
on page 8 to wire the connector).
on the next page to
DTP T USW 233 • Installation and Operation
AUDIO
Tip (+)
Ring (-)
Sleeve ( )
3.5 mm Stereo Plug Connector
(balanced)
on
RS-232
IR
IR and
Tx
Rx
G
Tx
SIG
LINK
DTP OUT
CONTACT
1
2
3
Selecting the
Rx
G
4

Advertisement

Table of Contents
loading

Table of Contents