Relay
ATTENTION
Please pay attention to the maximum switch current of 200 mA respectively the
maximum switch voltage of 48V per relay output.
!
The following description applies for both configuration windows Relay 1 and Re-
lay 2.
FIG. 17
The options for the relay configuration are identical with the configuration of a TTL-
Pin. The following Function Codes are available:
– Always Open: The relay is always open.
– Always Closed: The relay is always closed. This can be used for example for
surveillance of the power supply.
– Connection State: Via Connection State you can signalise the connection
state of a line. The following configurations are possible:
– Disconnect
– Connect
– System Alarm Pending: If one of the possible system errors (see CHAPTER
5.7.1) occurs, it can be signalised by selecting this option.
– MPEG Encoder running: If the encoder detect no error, the relay will be
closed.
– PAD available: If the PAD insertion is activated (see CHAPTER 5.5.2.1.2,
Page 36) and the encoder receives data the relay will be closed.
RELAY
W i n d o w s
P C
S o f t w a r e
PAG E 4 3