Recommended Replacement Parts; Recommended Replacement Parts (Table 10) - Canon imageFORMULA DR-G1100 Series Service Manual

Hide thumbs Also See for imageFORMULA DR-G1100 Series:
Table of Contents

Advertisement

H. Recommended Replacement Parts
The Recommended Replacement Parts in the following table are suggested to be
kept in stock by the Dealer, for replacement purposes, in the event of a hardware
failure.
Note: All recommended replacement parts shown in the below table are for
reference purposes only and are subject to change without notice.

Recommended Replacement Parts (Table 10)

Part Name
Registration roller lower
Bearing
Platen roller
Bearing
Reading roller lower
Bearing
Front U-turn roller (drive)
(ROLLER, U-TURN PRE,
LOWER *1)
Bearing
Rear U-turn roller (drive)
(ROLLER, U-TURN,
LOWER *1)
Bearing
Eject roller (drive)
Bearing
Registration roller upper-
front
Bearing
Reading roller upper
(ROLLER,
REGISTRATION UPPER
*1)
Bearing
Front U-turn roller
(follower) (ROLLER,
READING UPPER *1)
Bearing
Rear U-turn roller
(follower) (ROLLER, U-
TURN, UPPER *1)
Bearing
Eject roller (follower)
Upper reading unit (front)
Lower reading unit (Back)
1
Item Numbers and Part Numbers are subject to change due to engineering changes, etc.
imageFORMULA DR-G1130/DR-G1100 Series Service Guide
Rev. 1
imageFORMULA DR-G1130/DR-G1100 Series Service Guide
1
Quantity
Part Number
MF1-4795-000
1
MS2-9004-000
2
MA2-8591-000
2
MS2-9003-000
4
MF1-4597-000
1
MS2-9004-000
2
1
MA2-8646-000
MS2-9004-000
4
MA2-8647-000
1
MS2-9004-000
2
MA2-8733-000
1
MS2-9004-000
2
1
MF1-4797-000
MS2-9003-000
2
MF1-4242-000
1
MS2-9003-000
2
MA2-6847-000
1
MS2-9003-000
2
MA2-8665-000
2
MS2-9003-000
4
MG1-4801-000
1
MG1-8318-000
1
MG1-8319-000
1
Remarks
Because of the worn rollers, it is
necessary to replace them when
a document jams or feed failures
occur after the roller cleaning.
Note:
1) The parts that are marked *1
are used in the parts catalog.
2) Because of the expected life of
electrical conductivity, replace the
bearing at the same time. The
parts numbers are different, but
specifications are the same as the
imageFORMULA DR-9050C.
3) The registration roller upper-
front and reading roller upper are
the same shape, but its color of
gear is different. Registration
roller one is black and the reading
roller is white.
Replace if an image failure occurs.