PG-X2 (For Flux Vector Control Mode Only)
Terminal
TA1
TA2
TA3
NOTE:
5 VDC and 12 VDC cannot be used at the same time.
3.7.3
Wiring a PG Speed Option Card
Wiring examples are provided in the following illustrations for the PG Speed Option Cards.
§
PG-A2 (For V/f with PG Feedback Mode Only)
12 V Voltage Input
Firmware – S1043
Revision: 2 (9/98)
Table 3.13
PG-X2 Terminal Specifications
No.
Contents
1
2
Power Supply for pulse generator
3
A-Phase + input terminal
4
A-Phase − input terminal
5
B-Phase + input terminal
6
B-Phase − input terminal
7
Z-Phase + input terminal
8
Z-Phase − input terminal
9
10
Common terminal
A-Phase + output terminal
1
A-Phase − output terminal
2
B-Phase + output terminal
3
B-Phase − output terminal
4
Z-Phase + input terminal
5
Z-Phase − input terminal
6
7
Control circuit common
(E)
Shield connection terminal
Figure 3.23
Wiring a 12 V Voltage Input
45
Chapter 3: Wiring
Specifications
12 VDC(±5%), 200 mA maximum (see note)
0 VDC (GND for power supply)
5 VDC ((±5%), 200 mA maximum (see note)
Line driver input (RS-422 level input)
(maximum response frequency: 300 kHz)
0 VDC (GND for power supply)
Line driver output (RS-422 level output)
Control circuit GND
—
© Saftronics, Inc.