USER MANUAL T45-K Thank you for purchasing COMMAX products. Please carefully read this User’ s Guide (in particular, precautions for safety) before using a product and follow instructions to use a product exactly. The company is not responsible for any safety accidents caused by abnormal operation of the product.
Getting Started Cautions Product description Includid items Parts and their functions Dimensions Fingerprint registration Verification mode Functions key Start Displays Menu navigation buttons Access to the system menu Operationg menu User Enroll Delete Amend Set temp ID COMMAX Access Control Solutions...
Page 3
Product Type, Engine Version, Firmware Version Advanced▶ View General Log, View Management Log, View User Info 5.TEST Test All/ Test Memory/ Test LCD/ Test Sound(AUTO)/ Test Sound(MANUAL)/ Test Sensor/ Test RTC/ Test cast status/ Test Card Reader COMMAX Access Control Solutions...
Page 4
When cleaning, do not use liquid solvent or wet cloth. Wipe with soft cloth. Never disassemble or modify this device in any way. (KJTECH Co., Ltd is not liable for porblems caused by unauthorized modification or attempted repair ) COMMAX Access Control Solutions...
500K, 100K VOIP function Door phone function OE(Power of Ethernet) Loading function 125Khz (EM/HID/Prox) RF Card 13.56Mhz (Mi fare/I-calss SE/ Felice) 26/34/37/40 bit Wie gand input / Output KEY PAD 4.3inches full touch Product Size 143x143x42(mm) COMMAX Access Control Solutions...
This system comes with the following comeponents. T45-K Bracket Wiring harness by the 'wiring manual' to see it. T45-K Cable Screw / Program CD For Bracket 4ea T3x20mm 9PIN 6PIN 5PIN 4PIN For T45-K 2ea M3x6mm (Power, 485 CON) COMMAX Access Control Solutions...
Card Sensor such as time attendance Is used for user or enter/exit administration. authentication. USB & Micro SD USB & micro SD memory devices For connecting slot. Connector Cable for connection to Connector. COMMAX Access Control Solutions...
Notes on the fingerprint input You have to register fingerprint in proper way to enhance recognition rate. Recommended to use finger which has no damage. Recommended to register more than two fingerprint in case. Improper Way COMMAX Access Control Solutions...
Setting of operating mode in accordance with security level refer to environment setting > advanced setting > operating mode CD&FD ID&FD ID&CD OPEN ID&CD&FD CLOSE KJ-3500 supports various type of access mode : Combination of Fingerprint, Card and ID(PIN) COMMAX Access Control Solutions...
1. Press Function Key (F1~F4) only or press numbers after Function Key . 2. Present the card to enter. FD Authentication Scheme F1~F4 + Fingerprint 1. Press Function Key (F1~F4) only or Press numbers after Function Key . 2. Place Finger Print to enter. COMMAX Access Control Solutions...
*>1 2 3 4 > # Menu 1. Press * on the touch pad 2. Press # after putting 1, 2, 3, 4 3. Success entering system menu 4. Move to your desired menu to use F1 or F2 COMMAX Access Control Solutions...
Page 15
1. Press * on the touch pad 2. Press * with registered administrator ID 3. Certificate registered fingerprint or card of administrator 4. Success to access system menu 5. Move to menu that wants F1 or F2 COMMAX Access Control Solutions...
USER www.commax.com COMMAX Access Control Solutions...
Page 17
2.Press # with registered No. and ID as an administrator 3.Select users to press # 4.Select registration to press # 5.Use F1 or F2 to move, put ID and press # to designate authority It can register fingerprints, cards and pictures to put a button COMMAX Access Control Solutions...
Page 18
7.A card that would use for enter/exit should be read if puts on a screen. Press # to register a card 8.Register to press # after shooting button for photo. 9.Go back to a main menu to press F4 if all procedures are clear. COMMAX Access Control Solutions...
Page 19
Enter to System Menu 1.Select user to press # 2.Select Delete to press # 3.Put administrator's or user's ID for delete 4.It would be finished to press # after selecting fingerprint or card that wants to delete COMMAX Access Control Solutions...
Page 20
1. After entry system menu > user > enroll 2. After input ID of needing of amend #, and push OK. 3. After select fingerprint or card then amend 4. Return to initial screen COMMAX Access Control Solutions...
Page 21
ID leaves log data Pre-registered ID is not used as a temp ID. Enter to System Menu 1.Select User to press # 2.Select temporary ID setting to press # 3.Set ID to press # after temporary ID enters ※ It could put until 8 digits(max) COMMAX Access Control Solutions...
Page 22
SETTING www.commax.com COMMAX Access Control Solutions...
Page 23
2.Date Setup the date of the device 3.Language (Korean/English/Chinese) Choose the language 4.Volume It can be adjust volume 0 ~ 10 from device. 5.Background image It can be set background image COMMAX Access Control Solutions...
Page 24
Registered photo : indication photo when enroll Photo event save ▶ Do not save Saving when failure of authentication. Saving when success of authentication Save all VOIP image quality ▶ Setting 160 * 120/ 320 * 240 COMMAX Access Control Solutions...
Page 25
Both card and fingerprint required for Access - Card must be authorized before fingerprint authentication ⑭ ID&FP : Both ID and Fingerprint required for Access - must punch in ID before fingerprint authentication ⑮ ID&CD&FP : All three formas needed for access COMMAX Access Control Solutions...
Page 26
Reset all settings to the default 8.Clear General Log Delete all general log data 9.Claer Management Log Delete all management log data 10.Clear Enroll Data Delete entire user data including fingerprint, card data and it is unrecoverable COMMAX Access Control Solutions...
Page 27
Select the intrusion detectionor fire detection if setting of fire detection and working fire detection sensor, the door which connect device open forcely. 7.Reaccess Count No, 0~ 9 Limit reaccess count between no, 0 ~ 9times 8.Reaccess Limit Time Limit reaccess time between no. 0 ~ 600minutes COMMAX Access Control Solutions...
Page 28
11. Setting Reader Of Outer Fingerprint Setting using or not using of outer fingerprint reader. If the function will be vitalized, the fingerprint also can use reader function, it can be up the level of security. COMMAX Access Control Solutions...
Page 29
To connect device with software (Guardian) by TCP/IP ( LAN), it must set-up IP Address, Subnet Mask, Gateway, (All the above data is for reference only and an confirm the details in network environment of the PC to connect) COMMAX Access Control Solutions...
Page 30
5.Managing computer IP address If setting wireless network of item 4, it have to set IP address in the computer. 6.Communication Password If the communication password is not correct, it is impossible to communicate with the software COMMAX Access Control Solutions...
Page 31
Setup none-relay Funckey and buzzer alarm key. Refer to Software (Guardian) manual 7-4 controller Special function No act F-Key how to setup the No Act F-key. ※ Please refer setting way of controller/ special function / setting off day COMMAX Access Control Solutions...
Page 32
Events of user entries from the reader are stored. (Ex. For time & attendance) 10.Idle Settings LCD power cut off : 0 ~ 60minutes IDLE mode : 0 ~ 60minutes COMMAX Access Control Solutions...
Page 33
Setting>Log Settings 1.Management Log Warning (NO, 0~100) If the management logo exceeds the setting value, it alarms 2.General Log Warning (NO, 0~200) If the management logo exceeds the setting value, it alarms COMMAX Access Control Solutions...
Page 34
USB MEMORY www.commax.com COMMAX Access Control Solutions...
Page 35
2.Download All General log Download all general events 3.Download Management log Download new management events 4.Download All Management log Download all management events 5.Download User Info Download user data 6.Upload User info Upload user data 7.Upgrade Firmware Update Firmware COMMAX Access Control Solutions...
Page 36
SYSTEM INFO www.commax.com COMMAX Access Control Solutions...
Page 37
Tempalte numvers which is enrolled in the device 3.ID Card ID Card numbers which is enrolled in the device 4.General Log General log(access event) numbers 5.Management Log Management log (system event) nembers 6.Number of photo Saving the photo when access event COMMAX Access Control Solutions...
Page 38
2.Serial Number Displays the device serial number 3.Manufacturer Displays the device manufacturer. 4.Product Name Displays the device name. 5.Product Type Dispalys the device Type. 6.Engine Version Displays the engine version 7.Firmware Version Displays the firmware version COMMAX Access Control Solutions...
Page 39
System Info>Advanced 1.View General Log Search and view the general access event 2.View Management Log Search and view the system management event 3.View User info Search and view the numbers of the fingerprint and card COMMAX Access Control Solutions...
Page 40
TEST www.commax.com COMMAX Access Control Solutions...
Page 41
5.Test Sound (Manual) Test Voice announcement manually 6.Test Sensor Test Finger sensor 7.Test RTC Test RCT. 8.Test Case Status Test the status of the case. 9.Test Card Reader Test the card reading. 10.Test Camera Test the camera COMMAX Access Control Solutions...