ADJ UV 72IP User Instructions page 5

Table of Contents

Advertisement

UV 72IP
Power Supply:
The ADJ UV 72IP contains an automatic voltage
switch, which will auto sense the voltage when it is plugged into the
power source. With this switch there is no need to worry about the cor-
rect power voltage, this unit can be plugged in anywhere.
DMX-512:
DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures
and controllers. A DMX controller sends DMX data instructions from
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA "IN" and DATA "OUT" XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA
"OUT" terminal).
DMX Linking: DMX is a language allowing all makes and models of
different manufactures to be linked together and operate from a single
controller, as long as all fixtures and the controller are DMX compli-
ant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
DMX Cable Requirements:
512 protocol. The UV 72IP has 3 DMX channel modes, please see pages
9-10 for the different modes. The DMX address is set on the back panel
of the UV 72IP.
Cable Requirements: This fixture powered by powerCON TRUE1 power
cables. These cables are specifically designed to maintain the integrity
of the IP rating. When using this fixture outdoors be sure to ONLY use
the ADJ cables that have been manufactured to meet the IP rating.
"First" DMX Cables - Special DMX "First" cable may be purchased
from ADJ to provide a means of data communication with standard DMX
fixtures for indoor use. These cables will come with the IP rated connec-
tor on one end and either a 3-pin XLR male or female connector on the
other depending on model. Be sure to only use these cables for inter-
grading this fixture in a standard DMX chain.
ADJ Products, LLC - www.adj.com - UV 72IP User Manual Page 8
REMOTE
INPUT
OUTPUT
SOUND
CONTROL
INPUT
POWER
DMX512
DMX+,DMX-,COMMON
1
DMX512 O T
3
3-PIN XLR
The UV 72IP can be controlled via DMX-
2
UV 72IP
Set Up
"First" Power Cable – A special power "First" cable is included with
every fixture. This cable is used to provide power to your fixture. This
cable comes with the IP rated twist lock connector on one end and a
standard Edison 3-prong, grounded prong on the other end. Be sure to
only use this cable for power distribution and never attempt to connect
this cable to the DMX lines.
You can chain multiple fixtures together through serial linking. Using the
IP rated signal cables provided through ADJ (part# TRU113). Always
REMOTE
SOUND
CONTROL
INPUT
be sure to daisy-chain your in and out data connections, never split
or "Y" your DMX connections unless you are using an approved DMX
splitter such as the ADJ WiFly D6 Branch or the original D6 Branch
(Both not IP rated).
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
COMMON
DMX +
1
DMX512 IN
3
3-PIN XLR
DMX -
2
5-Pin XLR DMX Connectors.
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used,
these adaptors are readily available at most electric stores. The chart
below details a proper cable conversion.
Data Compliment (- signal)
Data True (+ signal)
ADJ Products, LLC - www.adj.com - UV 72IP User Manual Page 9
INPUT
OUTPUT
SOUND
POWER
When longer runs of cable are
Termination reduces signal errors and
avoids signal transmission problems
1
and interference. It is always advisable
3
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
Some manufactures use 5-pin DMX-
3-Pin XLR to 5-Pin XLR Conversion
Conductor
3-Pin XLR Female (Out)
Ground/Shield
Pin 1
Pin 2
Pin 3
Not Used
Not Used
Set Up
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
POWER
5-Pin XLR Male (In)
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use

Advertisement