5
Installation
When carrying out any work on the machine, observe the general safety instructions
(Page 77) and the specifications contained in EN 50110-1 regarding safe operation
of electrical equipment.
Note
Loss of conformity with European directives
In the delivery state, the machine corresponds to the requirements of the European
directives. Unauthorized changes or modifications to the machine lead to the loss of
conformity with European directives and the loss of warranty.
WARNING
Explosion hazard when making modifications to the machine
Substantial modifications to the machine are not permitted – or may only be
performed by the manufacturer. Otherwise an explosion can occur in an explosive
atmosphere. This can result in death, serious injury or material damage.
Please contact the Service Center, if necessary.
5.1

Preparing for installation

5.1.1

Requirements for installation

The following requirements must be satisfied prior to starting installation work:
● Staff have access to the operating and installation instructions.
● The machine is unpacked and ready for mounting at the installation location.
Note
Measure the insulation resistance of the winding before starting installation work
Wherever possible, measure the insulation resistance of the winding before
starting installation work. If the insulation resistance lies below the specified
value, take appropriate remedial measures. These remedial measures may
necessitate the machine being removed again and transported.