WARNING
Hazardous voltage
The winding can be damaged if objects are introduced into the
condensation holes (optional). This can lead to death, serious injury or
material damage.
Note the following to maintain the degree of protection:
Switch off the machine so that it is in a no-voltage condition before
you open the condensation drain holes.
Close the condensation drain holes, e.g. using T-plugs, before
commissioning the machine.
NOTICE
Reduction of the degree of protection
If condensation drain holes are not closed, then this can result in material damage
to the motor.
In order to maintain the degree of protection, after the condensation has been
drained, you must close all of the drain holes.
9.5
Repair
When carrying out any work on the machine, observe the general safety instructions
(Page 77) and the specifications contained in EN 50110-1 regarding safe operation
of electrical equipment.
Comply with the IEC / EN 60079-17 standard during all service and maintenance
work on the machine.
WARNING
Explosion hazard when carrying out repair work
Repairs are only permissible within the scope of the work described in these
operating instructions. Otherwise an explosion can occur in an explosive
atmosphere. This can result in death, serious injury or material damage.
For repairs to go beyond this scope, please contact the Service Center.