In addition to RS-485 mode, the radio is capable of operating in RS-422 mode. Config-
ure the port for RS-485 but follow the RS-422 wiring arrangements shown in below un-
der COM2 RS-485 and RS-422 Wiring Arrangement.
COM2 is hard-wired as a DCE device.
Table 6-7. COM2 Pin Descriptions—Radio in RS-232 Mode
Number
Table 6-8. COM2 Pin Descriptions—Radio in RS-485 Mode
Pin
Number
MDS 05-6399A01, Rev. E
Figure 6-6. COM2 Connector (RJ-45)
(As viewed from outside the radio)
Pin
Radio
Pin Description
Input/
Output
1
--
Reserved—Do not connect
2
--
Reserved—Do not connect
3
--
Reserved—Do not connect
4
-
Ground—Connects to ground (negative supply potential)
on the radio's PC board.
5
OUT
RXD (Received Data)—Supplies received data to the
connected device.
6
IN
TXD (Transmitted Data)—Accepts TX data from the
connected device.
7
OUT
CTS (Clear-to-Send)
8
IN
RTS (Request-to-Send)
Radio
Input/
Pin Description
Output