Table 2-3. 400MHz Master Station Technical Specifications
Transmit (TX) Parameter
Frequency Range
Frequency Stability
TX Power Out
TX Frequency Response
Agency Approvals
Load VSWR
Power Consumption
Receive (RX) Parameter
Frequency Range
RX Intermodulation
RX Adjacent Channel
RX Spurious and Image
RX Baseband Amplitude
RSSI Accuracy
RX High RF Input Level
RX Baseband Frequency Response
Power Consumption
Noise Figure
Blocking
Operating Range
1
Additional frequency bands under development
2
-30°C to +50°C when operating continuously keyed (CKEY)

2.3 FCC Emission Designators: How to Find Them

An FCC emission designator is a seven-character string that represents the bandwidth, modula-
tion, and other characteristics of a transmitted radio signal. This information is required when
applying for an FCC license. The designator assigned to your equipment depends on the particu-
lar sub-model of the product line you are licensing. In some cases, multiple designators are used
to cover product variants such as base stations, remotes, indoor/outdoor units, frequency band,
etc. An updated and official list of emission designators is maintained on the FCC's website at
the following link:
https://apps.fcc.gov/oetcf/eas/reports/GenericSearch.cfm
Once the site has been reached, proceed as follows to determine your designator:
1. At the top of form in the box labeled Grantee Code: enter
products.
2. At the bottom of the form in the box labeled
number (i.e.,
300
MDS 05-6399A01, Rev. E
Specification
400-450 MHz (SDM4B) 450-512MHz (SDM4C)
<0.5 ppm, -30C to +60C
+41.1 dBm maximum at radio card for-30 to +60C
+/- 1.0 dB from 100 Hz to 2.5 kHz
FCC Part 22
FCC Part 90
IC RSS-119
10:1 Max, All angles, No damage
<80W for all DC and AC versions, 100% TX Duty Cycle
Specification
400-450 MHz (SDM4B) 450-512MHz (SDM4C)
>60 dB
>60 dB
>60 dB
225 < Audio Level <275 mV RMS, -50 dBm @ 1 kHz
+/-3 dB for RSSI -110 to -70 dBm
10 dBm, no damage
+/- 1.0 dB from 100 Hz to 2.5 kHz
<30W for all DC and AC versions, transmitter disabled
<6 dB
>60 dB
-30°C to +60°C