Preparation

Step 1.1 Choosing the installation
location
Overview of installation location requirements
4.9inch
(125 mm)
or more
You can select the direction of
draining (left or right).
Maximum pipe height: 26.2/49.2ft(8/15m)
Maximum pipe length: 49.2/98.4ft(15/30m)
Make at least one round to
reduce noise and vibration.
The actual units may look different from
the images depicted here.
Model
09/12
Outdoor Unit
Outer wall
Indoor Unit
Cut insulation to have
rainwater drained
36 English
IBIM_EN.indd 36
3.9inch(100 mm) or more
4.9inch
(125 mm)
or more
Drain hose hole
Pipe length
Pipe height
Minimum
Maximum
Maximum
9.8ft(3m)
49.2ft(15m)
26.2ft(8m)
Make a U-trap (A) on the
pipe (which is connected to
CAUTION
the indoor unit) at outer wall
and cut the bottom part of
the insulation (about 10 mm)
to prevent rainwater from
getting inside through the
insulation.
CAUTION
Comply with the length and height limits
described in the figure above.
Minimum clearances for the outdoor unit
Wall
Minimum clearance in mm
23.6
Air flow direction
Top view
When installing 1 outdoor unit
5.9
23.6
11.8
Side view
(6 cases)
(Unit: inch)
78.74
3/17/2017 10:01:22 AM