Figure 2-7 Installing the Left Rack Mounting Bracket Assembly into the Rack

Mounting the Server in the Rack Cabinet

Use the following procedure to mount the server into the rack cabinet (see
Figure 2-8).
Anchor the Rack Cabinet. The rack cabinet must be
anchored to an unmovable support or a front stabilizer to
prevent it from falling over when one or more units are
extended in front of it on slide assemblies. The anchors must
be able to withstand a force of up to 113 kg (250 lbs.). You
must also consider the weight of any other device installed in
the rack.
Avoid Injury. It is required that two people are present when
lifting and assembling the rack-mount server into a rack
cabinet.
Do not attempt to lift or move the server unit by the latches
on the power supplies.
1. Pull the two extension rail assemblies (see Figure 2-8) out of each rack
mounting assembly on the rack cabinet until it locks in place.
A – Vertical mounting rail
B – Rack mounting assembly
C – Alignment tab
D – Screw
!
WARNING
Setting Up the System 2-11