Fig. 12
Minimum clearances (in cm)
Combustion gases
All gas heaters must be connected in a leak-roof manner to
a gas evacuation pipe of adequate dimensions.
The flue must:
– be vertical (reduced horizontal sections or no
horizontal sections at all)
– be thermally insulated
– have an exit above the maximum roof level
A flexible or rigid pipe should be used, fit it inside the flue
socket. The external diameter of the pipe should be slightly
smaller than the dimension specified in the appliances
dimensions table.
The extremity of the evacuation pipe must be protected
against wind/rain
CAUTION: Ensure that the extremity of the
evacuation pipe is placed between the ledge
and the ring of the flue.
Where these conditions are not possible to achieve, an
alternative location must be selected.
Flue ducts
If the flue duct goes through walls and/or furniture containing
flammable material:
▶ Thermal insulate the duct to ensure that the temperature of
the contact surface is less than 85 °C.
Surface temperature
The maximum surface temperature of the appliance is below
85 °C. Special protection measures are not required for
inflammable building materials or housings.
Therm 4200 – 6 720 821 605 (2017/08)
L
h
3
3
40
6720607539-02.6Av
Installation (must be carried out only by qualified technicians)
Air admission
The place where the heater is to be installed must have an area
of air supply according to the table.
Appliance
T4200 11-2D
T4200 14-2D
T4200 18-2D
Table 6
Useful areas for air admission
Minimum requirements are listed above. Local regulations
should always be observed.
5.3

Fixing the appliance

▶ Remove the temperature/flow selector and the power
selector.
▶ Unscrew the cover fixing screws.
▶ Remove the outer case by sliding it forwards and then
lifting upwards.
▶ Fix the appliance using the sleeves and hooks supplied so
that it is vertical.
CAUTION: Never allow the appliance to rest
against water or gas pipes.
5.4

Water connection

It is advisable to drain the appliance before installing it as any
dirt or grit inside it could reduce the water flow rate and, in
extreme cases, could completely clog up the appliance.
▶ Mark cold water [A] and hot water pipes [B], so as to
prevent confusion.
▶ Connect pipe to water valve using the connecting kit
supplied.
Fig. 13
Water connection
Minimum area
60 cm
2
90 cm
2
120 cm
2
13